West Wemyss Recognition Study September 15, 2024 n=75 Participants (West Wemyss) 8-week West Wemyss study

West Wemyss P300 Recognition Memory Research

Comprehensive controlled study conducted in West Wemyss documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for West Wemyss participants.

West Wemyss Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in West Wemyss

Ethics Approval: West Wemyss University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at West Wemyss facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for West Wemyss research

Study Period: September 15 - November 10, 2024 (8 weeks) in West Wemyss

West Wemyss Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with West Wemyss participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy West Wemyss participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All West Wemyss participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: West Wemyss guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout West Wemyss testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in West Wemyss with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
West Wemyss Participants
95.2%
West Wemyss Accuracy
318ms
West Wemyss P300 Latency
11.3μV
West Wemyss Peak Amplitude

West Wemyss Plain-English Summary

In simple terms, this West Wemyss study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in West Wemyss.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled West Wemyss research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in West Wemyss, particularly for cases where objective, research-backed evidence is important.

West Wemyss Pre-Test System Calibration

All West Wemyss testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before West Wemyss participant testing commenced.

West Wemyss Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All West Wemyss channels within ±0.2% tolerance

West Wemyss Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All West Wemyss parameters within specification limits

West Wemyss Research Methodology

Week 1: West Wemyss Participant Recruitment & Randomization

75 healthy adults recruited through West Wemyss university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All West Wemyss participants provided informed consent and completed health screening questionnaires.

Week 1-2: West Wemyss Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at West Wemyss facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: West Wemyss Controlled Testing Protocol

West Wemyss innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at West Wemyss laboratory.

Week 6-7: West Wemyss Polygraph Comparison Testing

All West Wemyss participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: West Wemyss Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout West Wemyss study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

West Wemyss P300 Recognition Response Analysis

West Wemyss Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms West Wemyss Guilty P300 318ms, 11.3μV West Wemyss Innocent P300 315ms, 4.2μV West Wemyss Guilty Knowledge (n=35) West Wemyss Innocent Control (n=40)

Figure 1: West Wemyss grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both West Wemyss groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

West Wemyss 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for West Wemyss guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

West Wemyss Statistical Analysis & Performance Metrics

West Wemyss Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
West Wemyss Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
West Wemyss Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
West Wemyss Difference - 7.1 - 6.0 - 8.2 3 ± 42

West Wemyss Statistical Significance Testing:

  • West Wemyss Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • West Wemyss Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • West Wemyss Effect Size: η² = 0.681 (large effect)
  • West Wemyss Power Analysis: β = 0.999 (excellent statistical power)
  • West Wemyss Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

West Wemyss Detection Performance Metrics:

West Wemyss Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
West Wemyss 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
West Wemyss Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
West Wemyss Improvement Ratio +81% +120% +98% +101% Immediate

West Wemyss Post-Test System Validation

Following completion of all West Wemyss participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

West Wemyss Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

West Wemyss Maximum drift: ±0.03% over 8-week period (Excellent stability)

West Wemyss Recognition Memory Research Key Findings

  • West Wemyss 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • West Wemyss guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • West Wemyss system calibration remained stable within ±0.03% over 8-week study period
  • West Wemyss response time analysis confirmed 318±31ms P300 latency with real-time detection
  • West Wemyss EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in West Wemyss participants
  • West Wemyss pre/post calibration validation confirms measurement reliability and traceability

West Wemyss Discussion & Clinical Implications

This controlled study conducted in West Wemyss demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

West Wemyss Clinical Significance:

  • West Wemyss Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • West Wemyss Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • West Wemyss Response Time: Real-time P300 detection enables immediate assessment
  • West Wemyss Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • West Wemyss Quality Assurance: Complete calibration validation ensures measurement integrity
This West Wemyss research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, West Wemyss Lead Researcher

West Wemyss Practical Applications:

  • West Wemyss Forensic Psychology: Evidence-based assessment of concealed information
  • West Wemyss Security Screening: Reliable pre-employment and periodic assessments
  • West Wemyss Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • West Wemyss Research Applications: Validated tool for memory and recognition studies
  • West Wemyss Clinical Assessment: Objective neurological evaluation with documented accuracy

From West Wemyss Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this West Wemyss study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in West Wemyss are grounded in published science rather than subjective opinion.

How the West Wemyss Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in West Wemyss
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in West Wemyss are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from West Wemyss P300 Research?

This West Wemyss recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • West Wemyss forensic and legal teams: seeking research-backed lie detector evidence
  • West Wemyss clinicians: requiring objective EEG markers for recognition and memory
  • West Wemyss security & compliance departments: interested in advanced screening tools
  • West Wemyss universities & labs: looking to build on validated P300 protocols

West Wemyss Future Research Directions

This foundational West Wemyss research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

West Wemyss Planned Studies:

  • West Wemyss Multi-site Validation: Replication across multiple research centers
  • West Wemyss Population Diversity: Performance evaluation across demographic groups
  • West Wemyss Longitudinal Stability: Extended measurement stability over 1+ year periods
  • West Wemyss Complex Scenarios: Real-world application validation studies
  • West Wemyss Machine Learning Integration: AI-enhanced pattern recognition development

West Wemyss P300 Research & Testing Services

Based on the success of this West Wemyss research study, we now offer comprehensive P300 recognition memory testing services throughout the West Wemyss area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

West Wemyss Service Features:

  • West Wemyss Professional Testing: Certified EEG technicians serving West Wemyss research community
  • West Wemyss Complete Confidentiality: Strict privacy protection throughout West Wemyss area
  • West Wemyss Same-Day Results: Immediate analysis and reporting for West Wemyss clients
  • West Wemyss Academic Support: Research collaboration and data sharing for West Wemyss institutions
  • West Wemyss Mobile Testing: On-site testing at West Wemyss universities and research facilities
£2999
West Wemyss P300 Research Session
£4999
West Wemyss Full Study Package
£7999
West Wemyss Multi-Session Research
24/7
West Wemyss Research Support
"The West Wemyss P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, West Wemyss Cognitive Research Director

West Wemyss Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in West Wemyss?

P300 recognition memory research in West Wemyss involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our West Wemyss study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for West Wemyss research?

Our West Wemyss calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in West Wemyss.

What are the key findings of the West Wemyss P300 recognition memory study?

Key findings from West Wemyss include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All West Wemyss results show statistical significance and research reproducibility.

Is the West Wemyss research data available for academic use?

Yes, we provide access to anonymized West Wemyss research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does West Wemyss P300 recognition memory research support?

West Wemyss applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in West Wemyss?

Our West Wemyss validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.