Unsworth Recognition Study September 15, 2024 n=75 Participants (Unsworth) 8-week Unsworth study

Unsworth P300 Recognition Memory Research

Comprehensive controlled study conducted in Unsworth documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Unsworth participants.

Unsworth Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Unsworth

Ethics Approval: Unsworth University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Unsworth facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Unsworth research

Study Period: September 15 - November 10, 2024 (8 weeks) in Unsworth

Unsworth Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Unsworth participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Unsworth participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Unsworth participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Unsworth guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Unsworth testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Unsworth with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Unsworth Participants
95.2%
Unsworth Accuracy
318ms
Unsworth P300 Latency
11.3μV
Unsworth Peak Amplitude

Unsworth Plain-English Summary

In simple terms, this Unsworth study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Unsworth.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Unsworth research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Unsworth, particularly for cases where objective, research-backed evidence is important.

Unsworth Pre-Test System Calibration

All Unsworth testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Unsworth participant testing commenced.

Unsworth Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Unsworth channels within ±0.2% tolerance

Unsworth Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Unsworth parameters within specification limits

Unsworth Research Methodology

Week 1: Unsworth Participant Recruitment & Randomization

75 healthy adults recruited through Unsworth university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Unsworth participants provided informed consent and completed health screening questionnaires.

Week 1-2: Unsworth Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Unsworth facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Unsworth Controlled Testing Protocol

Unsworth innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Unsworth laboratory.

Week 6-7: Unsworth Polygraph Comparison Testing

All Unsworth participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Unsworth Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Unsworth study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Unsworth P300 Recognition Response Analysis

Unsworth Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Unsworth Guilty P300 318ms, 11.3μV Unsworth Innocent P300 315ms, 4.2μV Unsworth Guilty Knowledge (n=35) Unsworth Innocent Control (n=40)

Figure 1: Unsworth grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Unsworth groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Unsworth 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Unsworth guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Unsworth Statistical Analysis & Performance Metrics

Unsworth Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Unsworth Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Unsworth Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Unsworth Difference - 7.1 - 6.0 - 8.2 3 ± 42

Unsworth Statistical Significance Testing:

  • Unsworth Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Unsworth Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Unsworth Effect Size: η² = 0.681 (large effect)
  • Unsworth Power Analysis: β = 0.999 (excellent statistical power)
  • Unsworth Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Unsworth Detection Performance Metrics:

Unsworth Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Unsworth 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Unsworth Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Unsworth Improvement Ratio +81% +120% +98% +101% Immediate

Unsworth Post-Test System Validation

Following completion of all Unsworth participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Unsworth Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Unsworth Maximum drift: ±0.03% over 8-week period (Excellent stability)

Unsworth Recognition Memory Research Key Findings

  • Unsworth 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Unsworth guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Unsworth system calibration remained stable within ±0.03% over 8-week study period
  • Unsworth response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Unsworth EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Unsworth participants
  • Unsworth pre/post calibration validation confirms measurement reliability and traceability

Unsworth Discussion & Clinical Implications

This controlled study conducted in Unsworth demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Unsworth Clinical Significance:

  • Unsworth Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Unsworth Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Unsworth Response Time: Real-time P300 detection enables immediate assessment
  • Unsworth Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Unsworth Quality Assurance: Complete calibration validation ensures measurement integrity
This Unsworth research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Unsworth Lead Researcher

Unsworth Practical Applications:

  • Unsworth Forensic Psychology: Evidence-based assessment of concealed information
  • Unsworth Security Screening: Reliable pre-employment and periodic assessments
  • Unsworth Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Unsworth Research Applications: Validated tool for memory and recognition studies
  • Unsworth Clinical Assessment: Objective neurological evaluation with documented accuracy

From Unsworth Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Unsworth study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Unsworth are grounded in published science rather than subjective opinion.

How the Unsworth Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Unsworth
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Unsworth are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Unsworth P300 Research?

This Unsworth recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Unsworth forensic and legal teams: seeking research-backed lie detector evidence
  • Unsworth clinicians: requiring objective EEG markers for recognition and memory
  • Unsworth security & compliance departments: interested in advanced screening tools
  • Unsworth universities & labs: looking to build on validated P300 protocols

Unsworth Future Research Directions

This foundational Unsworth research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Unsworth Planned Studies:

  • Unsworth Multi-site Validation: Replication across multiple research centers
  • Unsworth Population Diversity: Performance evaluation across demographic groups
  • Unsworth Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Unsworth Complex Scenarios: Real-world application validation studies
  • Unsworth Machine Learning Integration: AI-enhanced pattern recognition development

Unsworth P300 Research & Testing Services

Based on the success of this Unsworth research study, we now offer comprehensive P300 recognition memory testing services throughout the Unsworth area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Unsworth Service Features:

  • Unsworth Professional Testing: Certified EEG technicians serving Unsworth research community
  • Unsworth Complete Confidentiality: Strict privacy protection throughout Unsworth area
  • Unsworth Same-Day Results: Immediate analysis and reporting for Unsworth clients
  • Unsworth Academic Support: Research collaboration and data sharing for Unsworth institutions
  • Unsworth Mobile Testing: On-site testing at Unsworth universities and research facilities
£2999
Unsworth P300 Research Session
£4999
Unsworth Full Study Package
£7999
Unsworth Multi-Session Research
24/7
Unsworth Research Support
"The Unsworth P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Unsworth Cognitive Research Director

Unsworth Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Unsworth?

P300 recognition memory research in Unsworth involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Unsworth study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Unsworth research?

Our Unsworth calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Unsworth.

What are the key findings of the Unsworth P300 recognition memory study?

Key findings from Unsworth include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Unsworth results show statistical significance and research reproducibility.

Is the Unsworth research data available for academic use?

Yes, we provide access to anonymized Unsworth research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Unsworth P300 recognition memory research support?

Unsworth applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Unsworth?

Our Unsworth validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.