Threave Recognition Study September 15, 2024 n=75 Participants (Threave) 8-week Threave study

Threave P300 Recognition Memory Research

Comprehensive controlled study conducted in Threave documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Threave participants.

Threave Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Threave

Ethics Approval: Threave University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Threave facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Threave research

Study Period: September 15 - November 10, 2024 (8 weeks) in Threave

Threave Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Threave participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Threave participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Threave participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Threave guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Threave testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Threave with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Threave Participants
95.2%
Threave Accuracy
318ms
Threave P300 Latency
11.3μV
Threave Peak Amplitude

Threave Plain-English Summary

In simple terms, this Threave study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Threave.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Threave research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Threave, particularly for cases where objective, research-backed evidence is important.

Threave Pre-Test System Calibration

All Threave testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Threave participant testing commenced.

Threave Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Threave channels within ±0.2% tolerance

Threave Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Threave parameters within specification limits

Threave Research Methodology

Week 1: Threave Participant Recruitment & Randomization

75 healthy adults recruited through Threave university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Threave participants provided informed consent and completed health screening questionnaires.

Week 1-2: Threave Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Threave facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Threave Controlled Testing Protocol

Threave innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Threave laboratory.

Week 6-7: Threave Polygraph Comparison Testing

All Threave participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Threave Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Threave study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Threave P300 Recognition Response Analysis

Threave Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Threave Guilty P300 318ms, 11.3μV Threave Innocent P300 315ms, 4.2μV Threave Guilty Knowledge (n=35) Threave Innocent Control (n=40)

Figure 1: Threave grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Threave groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Threave 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Threave guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Threave Statistical Analysis & Performance Metrics

Threave Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Threave Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Threave Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Threave Difference - 7.1 - 6.0 - 8.2 3 ± 42

Threave Statistical Significance Testing:

  • Threave Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Threave Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Threave Effect Size: η² = 0.681 (large effect)
  • Threave Power Analysis: β = 0.999 (excellent statistical power)
  • Threave Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Threave Detection Performance Metrics:

Threave Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Threave 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Threave Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Threave Improvement Ratio +81% +120% +98% +101% Immediate

Threave Post-Test System Validation

Following completion of all Threave participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Threave Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Threave Maximum drift: ±0.03% over 8-week period (Excellent stability)

Threave Recognition Memory Research Key Findings

  • Threave 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Threave guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Threave system calibration remained stable within ±0.03% over 8-week study period
  • Threave response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Threave EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Threave participants
  • Threave pre/post calibration validation confirms measurement reliability and traceability

Threave Discussion & Clinical Implications

This controlled study conducted in Threave demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Threave Clinical Significance:

  • Threave Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Threave Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Threave Response Time: Real-time P300 detection enables immediate assessment
  • Threave Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Threave Quality Assurance: Complete calibration validation ensures measurement integrity
This Threave research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Threave Lead Researcher

Threave Practical Applications:

  • Threave Forensic Psychology: Evidence-based assessment of concealed information
  • Threave Security Screening: Reliable pre-employment and periodic assessments
  • Threave Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Threave Research Applications: Validated tool for memory and recognition studies
  • Threave Clinical Assessment: Objective neurological evaluation with documented accuracy

From Threave Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Threave study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Threave are grounded in published science rather than subjective opinion.

How the Threave Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Threave
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Threave are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Threave P300 Research?

This Threave recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Threave forensic and legal teams: seeking research-backed lie detector evidence
  • Threave clinicians: requiring objective EEG markers for recognition and memory
  • Threave security & compliance departments: interested in advanced screening tools
  • Threave universities & labs: looking to build on validated P300 protocols

Threave Future Research Directions

This foundational Threave research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Threave Planned Studies:

  • Threave Multi-site Validation: Replication across multiple research centers
  • Threave Population Diversity: Performance evaluation across demographic groups
  • Threave Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Threave Complex Scenarios: Real-world application validation studies
  • Threave Machine Learning Integration: AI-enhanced pattern recognition development

Threave P300 Research & Testing Services

Based on the success of this Threave research study, we now offer comprehensive P300 recognition memory testing services throughout the Threave area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Threave Service Features:

  • Threave Professional Testing: Certified EEG technicians serving Threave research community
  • Threave Complete Confidentiality: Strict privacy protection throughout Threave area
  • Threave Same-Day Results: Immediate analysis and reporting for Threave clients
  • Threave Academic Support: Research collaboration and data sharing for Threave institutions
  • Threave Mobile Testing: On-site testing at Threave universities and research facilities
£2999
Threave P300 Research Session
£4999
Threave Full Study Package
£7999
Threave Multi-Session Research
24/7
Threave Research Support
"The Threave P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Threave Cognitive Research Director

Threave Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Threave?

P300 recognition memory research in Threave involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Threave study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Threave research?

Our Threave calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Threave.

What are the key findings of the Threave P300 recognition memory study?

Key findings from Threave include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Threave results show statistical significance and research reproducibility.

Is the Threave research data available for academic use?

Yes, we provide access to anonymized Threave research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Threave P300 recognition memory research support?

Threave applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Threave?

Our Threave validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.