St Annes Recognition Study September 15, 2024 n=75 Participants (St Annes) 8-week St Annes study

St Annes P300 Recognition Memory Research

Comprehensive controlled study conducted in St Annes documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for St Annes participants.

St Annes Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in St Annes

Ethics Approval: St Annes University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at St Annes facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for St Annes research

Study Period: September 15 - November 10, 2024 (8 weeks) in St Annes

St Annes Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with St Annes participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy St Annes participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All St Annes participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: St Annes guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout St Annes testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in St Annes with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
St Annes Participants
95.2%
St Annes Accuracy
318ms
St Annes P300 Latency
11.3μV
St Annes Peak Amplitude

St Annes Plain-English Summary

In simple terms, this St Annes study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in St Annes.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled St Annes research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in St Annes, particularly for cases where objective, research-backed evidence is important.

St Annes Pre-Test System Calibration

All St Annes testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before St Annes participant testing commenced.

St Annes Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All St Annes channels within ±0.2% tolerance

St Annes Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All St Annes parameters within specification limits

St Annes Research Methodology

Week 1: St Annes Participant Recruitment & Randomization

75 healthy adults recruited through St Annes university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All St Annes participants provided informed consent and completed health screening questionnaires.

Week 1-2: St Annes Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at St Annes facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: St Annes Controlled Testing Protocol

St Annes innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at St Annes laboratory.

Week 6-7: St Annes Polygraph Comparison Testing

All St Annes participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: St Annes Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout St Annes study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

St Annes P300 Recognition Response Analysis

St Annes Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms St Annes Guilty P300 318ms, 11.3μV St Annes Innocent P300 315ms, 4.2μV St Annes Guilty Knowledge (n=35) St Annes Innocent Control (n=40)

Figure 1: St Annes grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both St Annes groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

St Annes 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for St Annes guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

St Annes Statistical Analysis & Performance Metrics

St Annes Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
St Annes Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
St Annes Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
St Annes Difference - 7.1 - 6.0 - 8.2 3 ± 42

St Annes Statistical Significance Testing:

  • St Annes Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • St Annes Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • St Annes Effect Size: η² = 0.681 (large effect)
  • St Annes Power Analysis: β = 0.999 (excellent statistical power)
  • St Annes Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

St Annes Detection Performance Metrics:

St Annes Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
St Annes 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
St Annes Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
St Annes Improvement Ratio +81% +120% +98% +101% Immediate

St Annes Post-Test System Validation

Following completion of all St Annes participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

St Annes Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

St Annes Maximum drift: ±0.03% over 8-week period (Excellent stability)

St Annes Recognition Memory Research Key Findings

  • St Annes 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • St Annes guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • St Annes system calibration remained stable within ±0.03% over 8-week study period
  • St Annes response time analysis confirmed 318±31ms P300 latency with real-time detection
  • St Annes EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in St Annes participants
  • St Annes pre/post calibration validation confirms measurement reliability and traceability

St Annes Discussion & Clinical Implications

This controlled study conducted in St Annes demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

St Annes Clinical Significance:

  • St Annes Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • St Annes Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • St Annes Response Time: Real-time P300 detection enables immediate assessment
  • St Annes Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • St Annes Quality Assurance: Complete calibration validation ensures measurement integrity
This St Annes research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, St Annes Lead Researcher

St Annes Practical Applications:

  • St Annes Forensic Psychology: Evidence-based assessment of concealed information
  • St Annes Security Screening: Reliable pre-employment and periodic assessments
  • St Annes Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • St Annes Research Applications: Validated tool for memory and recognition studies
  • St Annes Clinical Assessment: Objective neurological evaluation with documented accuracy

From St Annes Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this St Annes study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in St Annes are grounded in published science rather than subjective opinion.

How the St Annes Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in St Annes
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in St Annes are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from St Annes P300 Research?

This St Annes recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • St Annes forensic and legal teams: seeking research-backed lie detector evidence
  • St Annes clinicians: requiring objective EEG markers for recognition and memory
  • St Annes security & compliance departments: interested in advanced screening tools
  • St Annes universities & labs: looking to build on validated P300 protocols

St Annes Future Research Directions

This foundational St Annes research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

St Annes Planned Studies:

  • St Annes Multi-site Validation: Replication across multiple research centers
  • St Annes Population Diversity: Performance evaluation across demographic groups
  • St Annes Longitudinal Stability: Extended measurement stability over 1+ year periods
  • St Annes Complex Scenarios: Real-world application validation studies
  • St Annes Machine Learning Integration: AI-enhanced pattern recognition development

St Annes P300 Research & Testing Services

Based on the success of this St Annes research study, we now offer comprehensive P300 recognition memory testing services throughout the St Annes area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

St Annes Service Features:

  • St Annes Professional Testing: Certified EEG technicians serving St Annes research community
  • St Annes Complete Confidentiality: Strict privacy protection throughout St Annes area
  • St Annes Same-Day Results: Immediate analysis and reporting for St Annes clients
  • St Annes Academic Support: Research collaboration and data sharing for St Annes institutions
  • St Annes Mobile Testing: On-site testing at St Annes universities and research facilities
£2999
St Annes P300 Research Session
£4999
St Annes Full Study Package
£7999
St Annes Multi-Session Research
24/7
St Annes Research Support
"The St Annes P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, St Annes Cognitive Research Director

St Annes Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in St Annes?

P300 recognition memory research in St Annes involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our St Annes study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for St Annes research?

Our St Annes calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in St Annes.

What are the key findings of the St Annes P300 recognition memory study?

Key findings from St Annes include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All St Annes results show statistical significance and research reproducibility.

Is the St Annes research data available for academic use?

Yes, we provide access to anonymized St Annes research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does St Annes P300 recognition memory research support?

St Annes applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in St Annes?

Our St Annes validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.