St Andrews Recognition Study September 15, 2024 n=75 Participants (St Andrews) 8-week St Andrews study

St Andrews P300 Recognition Memory Research

Comprehensive controlled study conducted in St Andrews documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for St Andrews participants.

St Andrews Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in St Andrews

Ethics Approval: St Andrews University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at St Andrews facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for St Andrews research

Study Period: September 15 - November 10, 2024 (8 weeks) in St Andrews

St Andrews Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with St Andrews participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy St Andrews participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All St Andrews participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: St Andrews guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout St Andrews testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in St Andrews with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
St Andrews Participants
95.2%
St Andrews Accuracy
318ms
St Andrews P300 Latency
11.3μV
St Andrews Peak Amplitude

St Andrews Plain-English Summary

In simple terms, this St Andrews study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in St Andrews.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled St Andrews research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in St Andrews, particularly for cases where objective, research-backed evidence is important.

St Andrews Pre-Test System Calibration

All St Andrews testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before St Andrews participant testing commenced.

St Andrews Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All St Andrews channels within ±0.2% tolerance

St Andrews Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All St Andrews parameters within specification limits

St Andrews Research Methodology

Week 1: St Andrews Participant Recruitment & Randomization

75 healthy adults recruited through St Andrews university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All St Andrews participants provided informed consent and completed health screening questionnaires.

Week 1-2: St Andrews Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at St Andrews facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: St Andrews Controlled Testing Protocol

St Andrews innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at St Andrews laboratory.

Week 6-7: St Andrews Polygraph Comparison Testing

All St Andrews participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: St Andrews Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout St Andrews study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

St Andrews P300 Recognition Response Analysis

St Andrews Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms St Andrews Guilty P300 318ms, 11.3μV St Andrews Innocent P300 315ms, 4.2μV St Andrews Guilty Knowledge (n=35) St Andrews Innocent Control (n=40)

Figure 1: St Andrews grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both St Andrews groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

St Andrews 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for St Andrews guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

St Andrews Statistical Analysis & Performance Metrics

St Andrews Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
St Andrews Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
St Andrews Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
St Andrews Difference - 7.1 - 6.0 - 8.2 3 ± 42

St Andrews Statistical Significance Testing:

  • St Andrews Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • St Andrews Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • St Andrews Effect Size: η² = 0.681 (large effect)
  • St Andrews Power Analysis: β = 0.999 (excellent statistical power)
  • St Andrews Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

St Andrews Detection Performance Metrics:

St Andrews Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
St Andrews 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
St Andrews Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
St Andrews Improvement Ratio +81% +120% +98% +101% Immediate

St Andrews Post-Test System Validation

Following completion of all St Andrews participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

St Andrews Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

St Andrews Maximum drift: ±0.03% over 8-week period (Excellent stability)

St Andrews Recognition Memory Research Key Findings

  • St Andrews 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • St Andrews guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • St Andrews system calibration remained stable within ±0.03% over 8-week study period
  • St Andrews response time analysis confirmed 318±31ms P300 latency with real-time detection
  • St Andrews EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in St Andrews participants
  • St Andrews pre/post calibration validation confirms measurement reliability and traceability

St Andrews Discussion & Clinical Implications

This controlled study conducted in St Andrews demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

St Andrews Clinical Significance:

  • St Andrews Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • St Andrews Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • St Andrews Response Time: Real-time P300 detection enables immediate assessment
  • St Andrews Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • St Andrews Quality Assurance: Complete calibration validation ensures measurement integrity
This St Andrews research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, St Andrews Lead Researcher

St Andrews Practical Applications:

  • St Andrews Forensic Psychology: Evidence-based assessment of concealed information
  • St Andrews Security Screening: Reliable pre-employment and periodic assessments
  • St Andrews Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • St Andrews Research Applications: Validated tool for memory and recognition studies
  • St Andrews Clinical Assessment: Objective neurological evaluation with documented accuracy

From St Andrews Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this St Andrews study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in St Andrews are grounded in published science rather than subjective opinion.

How the St Andrews Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in St Andrews
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in St Andrews are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from St Andrews P300 Research?

This St Andrews recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • St Andrews forensic and legal teams: seeking research-backed lie detector evidence
  • St Andrews clinicians: requiring objective EEG markers for recognition and memory
  • St Andrews security & compliance departments: interested in advanced screening tools
  • St Andrews universities & labs: looking to build on validated P300 protocols

St Andrews Future Research Directions

This foundational St Andrews research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

St Andrews Planned Studies:

  • St Andrews Multi-site Validation: Replication across multiple research centers
  • St Andrews Population Diversity: Performance evaluation across demographic groups
  • St Andrews Longitudinal Stability: Extended measurement stability over 1+ year periods
  • St Andrews Complex Scenarios: Real-world application validation studies
  • St Andrews Machine Learning Integration: AI-enhanced pattern recognition development

St Andrews P300 Research & Testing Services

Based on the success of this St Andrews research study, we now offer comprehensive P300 recognition memory testing services throughout the St Andrews area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

St Andrews Service Features:

  • St Andrews Professional Testing: Certified EEG technicians serving St Andrews research community
  • St Andrews Complete Confidentiality: Strict privacy protection throughout St Andrews area
  • St Andrews Same-Day Results: Immediate analysis and reporting for St Andrews clients
  • St Andrews Academic Support: Research collaboration and data sharing for St Andrews institutions
  • St Andrews Mobile Testing: On-site testing at St Andrews universities and research facilities
£2999
St Andrews P300 Research Session
£4999
St Andrews Full Study Package
£7999
St Andrews Multi-Session Research
24/7
St Andrews Research Support
"The St Andrews P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, St Andrews Cognitive Research Director

St Andrews Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in St Andrews?

P300 recognition memory research in St Andrews involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our St Andrews study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for St Andrews research?

Our St Andrews calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in St Andrews.

What are the key findings of the St Andrews P300 recognition memory study?

Key findings from St Andrews include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All St Andrews results show statistical significance and research reproducibility.

Is the St Andrews research data available for academic use?

Yes, we provide access to anonymized St Andrews research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does St Andrews P300 recognition memory research support?

St Andrews applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in St Andrews?

Our St Andrews validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.