Slateford Recognition Study September 15, 2024 n=75 Participants (Slateford) 8-week Slateford study

Slateford P300 Recognition Memory Research

Comprehensive controlled study conducted in Slateford documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Slateford participants.

Slateford Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Slateford

Ethics Approval: Slateford University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Slateford facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Slateford research

Study Period: September 15 - November 10, 2024 (8 weeks) in Slateford

Slateford Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Slateford participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Slateford participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Slateford participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Slateford guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Slateford testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Slateford with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Slateford Participants
95.2%
Slateford Accuracy
318ms
Slateford P300 Latency
11.3μV
Slateford Peak Amplitude

Slateford Plain-English Summary

In simple terms, this Slateford study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Slateford.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Slateford research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Slateford, particularly for cases where objective, research-backed evidence is important.

Slateford Pre-Test System Calibration

All Slateford testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Slateford participant testing commenced.

Slateford Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Slateford channels within ±0.2% tolerance

Slateford Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Slateford parameters within specification limits

Slateford Research Methodology

Week 1: Slateford Participant Recruitment & Randomization

75 healthy adults recruited through Slateford university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Slateford participants provided informed consent and completed health screening questionnaires.

Week 1-2: Slateford Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Slateford facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Slateford Controlled Testing Protocol

Slateford innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Slateford laboratory.

Week 6-7: Slateford Polygraph Comparison Testing

All Slateford participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Slateford Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Slateford study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Slateford P300 Recognition Response Analysis

Slateford Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Slateford Guilty P300 318ms, 11.3μV Slateford Innocent P300 315ms, 4.2μV Slateford Guilty Knowledge (n=35) Slateford Innocent Control (n=40)

Figure 1: Slateford grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Slateford groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Slateford 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Slateford guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Slateford Statistical Analysis & Performance Metrics

Slateford Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Slateford Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Slateford Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Slateford Difference - 7.1 - 6.0 - 8.2 3 ± 42

Slateford Statistical Significance Testing:

  • Slateford Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Slateford Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Slateford Effect Size: η² = 0.681 (large effect)
  • Slateford Power Analysis: β = 0.999 (excellent statistical power)
  • Slateford Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Slateford Detection Performance Metrics:

Slateford Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Slateford 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Slateford Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Slateford Improvement Ratio +81% +120% +98% +101% Immediate

Slateford Post-Test System Validation

Following completion of all Slateford participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Slateford Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Slateford Maximum drift: ±0.03% over 8-week period (Excellent stability)

Slateford Recognition Memory Research Key Findings

  • Slateford 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Slateford guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Slateford system calibration remained stable within ±0.03% over 8-week study period
  • Slateford response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Slateford EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Slateford participants
  • Slateford pre/post calibration validation confirms measurement reliability and traceability

Slateford Discussion & Clinical Implications

This controlled study conducted in Slateford demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Slateford Clinical Significance:

  • Slateford Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Slateford Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Slateford Response Time: Real-time P300 detection enables immediate assessment
  • Slateford Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Slateford Quality Assurance: Complete calibration validation ensures measurement integrity
This Slateford research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Slateford Lead Researcher

Slateford Practical Applications:

  • Slateford Forensic Psychology: Evidence-based assessment of concealed information
  • Slateford Security Screening: Reliable pre-employment and periodic assessments
  • Slateford Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Slateford Research Applications: Validated tool for memory and recognition studies
  • Slateford Clinical Assessment: Objective neurological evaluation with documented accuracy

From Slateford Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Slateford study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Slateford are grounded in published science rather than subjective opinion.

How the Slateford Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Slateford
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Slateford are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Slateford P300 Research?

This Slateford recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Slateford forensic and legal teams: seeking research-backed lie detector evidence
  • Slateford clinicians: requiring objective EEG markers for recognition and memory
  • Slateford security & compliance departments: interested in advanced screening tools
  • Slateford universities & labs: looking to build on validated P300 protocols

Slateford Future Research Directions

This foundational Slateford research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Slateford Planned Studies:

  • Slateford Multi-site Validation: Replication across multiple research centers
  • Slateford Population Diversity: Performance evaluation across demographic groups
  • Slateford Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Slateford Complex Scenarios: Real-world application validation studies
  • Slateford Machine Learning Integration: AI-enhanced pattern recognition development

Slateford P300 Research & Testing Services

Based on the success of this Slateford research study, we now offer comprehensive P300 recognition memory testing services throughout the Slateford area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Slateford Service Features:

  • Slateford Professional Testing: Certified EEG technicians serving Slateford research community
  • Slateford Complete Confidentiality: Strict privacy protection throughout Slateford area
  • Slateford Same-Day Results: Immediate analysis and reporting for Slateford clients
  • Slateford Academic Support: Research collaboration and data sharing for Slateford institutions
  • Slateford Mobile Testing: On-site testing at Slateford universities and research facilities
£2999
Slateford P300 Research Session
£4999
Slateford Full Study Package
£7999
Slateford Multi-Session Research
24/7
Slateford Research Support
"The Slateford P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Slateford Cognitive Research Director

Slateford Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Slateford?

P300 recognition memory research in Slateford involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Slateford study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Slateford research?

Our Slateford calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Slateford.

What are the key findings of the Slateford P300 recognition memory study?

Key findings from Slateford include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Slateford results show statistical significance and research reproducibility.

Is the Slateford research data available for academic use?

Yes, we provide access to anonymized Slateford research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Slateford P300 recognition memory research support?

Slateford applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Slateford?

Our Slateford validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.