Shrewsbury Recognition Study September 15, 2024 n=75 Participants (Shrewsbury) 8-week Shrewsbury study

Shrewsbury P300 Recognition Memory Research

Comprehensive controlled study conducted in Shrewsbury documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Shrewsbury participants.

Shrewsbury Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Shrewsbury

Ethics Approval: Shrewsbury University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Shrewsbury facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Shrewsbury research

Study Period: September 15 - November 10, 2024 (8 weeks) in Shrewsbury

Shrewsbury Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Shrewsbury participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Shrewsbury participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Shrewsbury participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Shrewsbury guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Shrewsbury testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Shrewsbury with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Shrewsbury Participants
95.2%
Shrewsbury Accuracy
318ms
Shrewsbury P300 Latency
11.3μV
Shrewsbury Peak Amplitude

Shrewsbury Plain-English Summary

In simple terms, this Shrewsbury study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Shrewsbury.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Shrewsbury research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Shrewsbury, particularly for cases where objective, research-backed evidence is important.

Shrewsbury Pre-Test System Calibration

All Shrewsbury testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Shrewsbury participant testing commenced.

Shrewsbury Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Shrewsbury channels within ±0.2% tolerance

Shrewsbury Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Shrewsbury parameters within specification limits

Shrewsbury Research Methodology

Week 1: Shrewsbury Participant Recruitment & Randomization

75 healthy adults recruited through Shrewsbury university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Shrewsbury participants provided informed consent and completed health screening questionnaires.

Week 1-2: Shrewsbury Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Shrewsbury facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Shrewsbury Controlled Testing Protocol

Shrewsbury innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Shrewsbury laboratory.

Week 6-7: Shrewsbury Polygraph Comparison Testing

All Shrewsbury participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Shrewsbury Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Shrewsbury study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Shrewsbury P300 Recognition Response Analysis

Shrewsbury Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Shrewsbury Guilty P300 318ms, 11.3μV Shrewsbury Innocent P300 315ms, 4.2μV Shrewsbury Guilty Knowledge (n=35) Shrewsbury Innocent Control (n=40)

Figure 1: Shrewsbury grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Shrewsbury groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Shrewsbury 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Shrewsbury guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Shrewsbury Statistical Analysis & Performance Metrics

Shrewsbury Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Shrewsbury Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Shrewsbury Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Shrewsbury Difference - 7.1 - 6.0 - 8.2 3 ± 42

Shrewsbury Statistical Significance Testing:

  • Shrewsbury Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Shrewsbury Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Shrewsbury Effect Size: η² = 0.681 (large effect)
  • Shrewsbury Power Analysis: β = 0.999 (excellent statistical power)
  • Shrewsbury Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Shrewsbury Detection Performance Metrics:

Shrewsbury Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Shrewsbury 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Shrewsbury Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Shrewsbury Improvement Ratio +81% +120% +98% +101% Immediate

Shrewsbury Post-Test System Validation

Following completion of all Shrewsbury participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Shrewsbury Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Shrewsbury Maximum drift: ±0.03% over 8-week period (Excellent stability)

Shrewsbury Recognition Memory Research Key Findings

  • Shrewsbury 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Shrewsbury guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Shrewsbury system calibration remained stable within ±0.03% over 8-week study period
  • Shrewsbury response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Shrewsbury EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Shrewsbury participants
  • Shrewsbury pre/post calibration validation confirms measurement reliability and traceability

Shrewsbury Discussion & Clinical Implications

This controlled study conducted in Shrewsbury demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Shrewsbury Clinical Significance:

  • Shrewsbury Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Shrewsbury Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Shrewsbury Response Time: Real-time P300 detection enables immediate assessment
  • Shrewsbury Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Shrewsbury Quality Assurance: Complete calibration validation ensures measurement integrity
This Shrewsbury research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Shrewsbury Lead Researcher

Shrewsbury Practical Applications:

  • Shrewsbury Forensic Psychology: Evidence-based assessment of concealed information
  • Shrewsbury Security Screening: Reliable pre-employment and periodic assessments
  • Shrewsbury Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Shrewsbury Research Applications: Validated tool for memory and recognition studies
  • Shrewsbury Clinical Assessment: Objective neurological evaluation with documented accuracy

From Shrewsbury Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Shrewsbury study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Shrewsbury are grounded in published science rather than subjective opinion.

How the Shrewsbury Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Shrewsbury
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Shrewsbury are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Shrewsbury P300 Research?

This Shrewsbury recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Shrewsbury forensic and legal teams: seeking research-backed lie detector evidence
  • Shrewsbury clinicians: requiring objective EEG markers for recognition and memory
  • Shrewsbury security & compliance departments: interested in advanced screening tools
  • Shrewsbury universities & labs: looking to build on validated P300 protocols

Shrewsbury Future Research Directions

This foundational Shrewsbury research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Shrewsbury Planned Studies:

  • Shrewsbury Multi-site Validation: Replication across multiple research centers
  • Shrewsbury Population Diversity: Performance evaluation across demographic groups
  • Shrewsbury Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Shrewsbury Complex Scenarios: Real-world application validation studies
  • Shrewsbury Machine Learning Integration: AI-enhanced pattern recognition development

Shrewsbury P300 Research & Testing Services

Based on the success of this Shrewsbury research study, we now offer comprehensive P300 recognition memory testing services throughout the Shrewsbury area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Shrewsbury Service Features:

  • Shrewsbury Professional Testing: Certified EEG technicians serving Shrewsbury research community
  • Shrewsbury Complete Confidentiality: Strict privacy protection throughout Shrewsbury area
  • Shrewsbury Same-Day Results: Immediate analysis and reporting for Shrewsbury clients
  • Shrewsbury Academic Support: Research collaboration and data sharing for Shrewsbury institutions
  • Shrewsbury Mobile Testing: On-site testing at Shrewsbury universities and research facilities
£2999
Shrewsbury P300 Research Session
£4999
Shrewsbury Full Study Package
£7999
Shrewsbury Multi-Session Research
24/7
Shrewsbury Research Support
"The Shrewsbury P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Shrewsbury Cognitive Research Director

Shrewsbury Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Shrewsbury?

P300 recognition memory research in Shrewsbury involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Shrewsbury study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Shrewsbury research?

Our Shrewsbury calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Shrewsbury.

What are the key findings of the Shrewsbury P300 recognition memory study?

Key findings from Shrewsbury include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Shrewsbury results show statistical significance and research reproducibility.

Is the Shrewsbury research data available for academic use?

Yes, we provide access to anonymized Shrewsbury research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Shrewsbury P300 recognition memory research support?

Shrewsbury applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Shrewsbury?

Our Shrewsbury validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.