Second Coast Recognition Study September 15, 2024 n=75 Participants (Second Coast) 8-week Second Coast study

Second Coast P300 Recognition Memory Research

Comprehensive controlled study conducted in Second Coast documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Second Coast participants.

Second Coast Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Second Coast

Ethics Approval: Second Coast University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Second Coast facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Second Coast research

Study Period: September 15 - November 10, 2024 (8 weeks) in Second Coast

Second Coast Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Second Coast participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Second Coast participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Second Coast participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Second Coast guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Second Coast testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Second Coast with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Second Coast Participants
95.2%
Second Coast Accuracy
318ms
Second Coast P300 Latency
11.3μV
Second Coast Peak Amplitude

Second Coast Plain-English Summary

In simple terms, this Second Coast study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Second Coast.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Second Coast research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Second Coast, particularly for cases where objective, research-backed evidence is important.

Second Coast Pre-Test System Calibration

All Second Coast testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Second Coast participant testing commenced.

Second Coast Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Second Coast channels within ±0.2% tolerance

Second Coast Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Second Coast parameters within specification limits

Second Coast Research Methodology

Week 1: Second Coast Participant Recruitment & Randomization

75 healthy adults recruited through Second Coast university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Second Coast participants provided informed consent and completed health screening questionnaires.

Week 1-2: Second Coast Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Second Coast facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Second Coast Controlled Testing Protocol

Second Coast innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Second Coast laboratory.

Week 6-7: Second Coast Polygraph Comparison Testing

All Second Coast participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Second Coast Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Second Coast study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Second Coast P300 Recognition Response Analysis

Second Coast Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Second Coast Guilty P300 318ms, 11.3μV Second Coast Innocent P300 315ms, 4.2μV Second Coast Guilty Knowledge (n=35) Second Coast Innocent Control (n=40)

Figure 1: Second Coast grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Second Coast groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Second Coast 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Second Coast guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Second Coast Statistical Analysis & Performance Metrics

Second Coast Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Second Coast Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Second Coast Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Second Coast Difference - 7.1 - 6.0 - 8.2 3 ± 42

Second Coast Statistical Significance Testing:

  • Second Coast Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Second Coast Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Second Coast Effect Size: η² = 0.681 (large effect)
  • Second Coast Power Analysis: β = 0.999 (excellent statistical power)
  • Second Coast Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Second Coast Detection Performance Metrics:

Second Coast Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Second Coast 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Second Coast Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Second Coast Improvement Ratio +81% +120% +98% +101% Immediate

Second Coast Post-Test System Validation

Following completion of all Second Coast participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Second Coast Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Second Coast Maximum drift: ±0.03% over 8-week period (Excellent stability)

Second Coast Recognition Memory Research Key Findings

  • Second Coast 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Second Coast guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Second Coast system calibration remained stable within ±0.03% over 8-week study period
  • Second Coast response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Second Coast EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Second Coast participants
  • Second Coast pre/post calibration validation confirms measurement reliability and traceability

Second Coast Discussion & Clinical Implications

This controlled study conducted in Second Coast demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Second Coast Clinical Significance:

  • Second Coast Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Second Coast Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Second Coast Response Time: Real-time P300 detection enables immediate assessment
  • Second Coast Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Second Coast Quality Assurance: Complete calibration validation ensures measurement integrity
This Second Coast research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Second Coast Lead Researcher

Second Coast Practical Applications:

  • Second Coast Forensic Psychology: Evidence-based assessment of concealed information
  • Second Coast Security Screening: Reliable pre-employment and periodic assessments
  • Second Coast Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Second Coast Research Applications: Validated tool for memory and recognition studies
  • Second Coast Clinical Assessment: Objective neurological evaluation with documented accuracy

From Second Coast Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Second Coast study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Second Coast are grounded in published science rather than subjective opinion.

How the Second Coast Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Second Coast
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Second Coast are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Second Coast P300 Research?

This Second Coast recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Second Coast forensic and legal teams: seeking research-backed lie detector evidence
  • Second Coast clinicians: requiring objective EEG markers for recognition and memory
  • Second Coast security & compliance departments: interested in advanced screening tools
  • Second Coast universities & labs: looking to build on validated P300 protocols

Second Coast Future Research Directions

This foundational Second Coast research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Second Coast Planned Studies:

  • Second Coast Multi-site Validation: Replication across multiple research centers
  • Second Coast Population Diversity: Performance evaluation across demographic groups
  • Second Coast Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Second Coast Complex Scenarios: Real-world application validation studies
  • Second Coast Machine Learning Integration: AI-enhanced pattern recognition development

Second Coast P300 Research & Testing Services

Based on the success of this Second Coast research study, we now offer comprehensive P300 recognition memory testing services throughout the Second Coast area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Second Coast Service Features:

  • Second Coast Professional Testing: Certified EEG technicians serving Second Coast research community
  • Second Coast Complete Confidentiality: Strict privacy protection throughout Second Coast area
  • Second Coast Same-Day Results: Immediate analysis and reporting for Second Coast clients
  • Second Coast Academic Support: Research collaboration and data sharing for Second Coast institutions
  • Second Coast Mobile Testing: On-site testing at Second Coast universities and research facilities
£2999
Second Coast P300 Research Session
£4999
Second Coast Full Study Package
£7999
Second Coast Multi-Session Research
24/7
Second Coast Research Support
"The Second Coast P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Second Coast Cognitive Research Director

Second Coast Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Second Coast?

P300 recognition memory research in Second Coast involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Second Coast study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Second Coast research?

Our Second Coast calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Second Coast.

What are the key findings of the Second Coast P300 recognition memory study?

Key findings from Second Coast include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Second Coast results show statistical significance and research reproducibility.

Is the Second Coast research data available for academic use?

Yes, we provide access to anonymized Second Coast research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Second Coast P300 recognition memory research support?

Second Coast applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Second Coast?

Our Second Coast validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.