Scotstoun Recognition Study September 15, 2024 n=75 Participants (Scotstoun) 8-week Scotstoun study

Scotstoun P300 Recognition Memory Research

Comprehensive controlled study conducted in Scotstoun documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Scotstoun participants.

Scotstoun Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Scotstoun

Ethics Approval: Scotstoun University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Scotstoun facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Scotstoun research

Study Period: September 15 - November 10, 2024 (8 weeks) in Scotstoun

Scotstoun Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Scotstoun participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Scotstoun participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Scotstoun participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Scotstoun guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Scotstoun testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Scotstoun with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Scotstoun Participants
95.2%
Scotstoun Accuracy
318ms
Scotstoun P300 Latency
11.3μV
Scotstoun Peak Amplitude

Scotstoun Plain-English Summary

In simple terms, this Scotstoun study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Scotstoun.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Scotstoun research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Scotstoun, particularly for cases where objective, research-backed evidence is important.

Scotstoun Pre-Test System Calibration

All Scotstoun testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Scotstoun participant testing commenced.

Scotstoun Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Scotstoun channels within ±0.2% tolerance

Scotstoun Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Scotstoun parameters within specification limits

Scotstoun Research Methodology

Week 1: Scotstoun Participant Recruitment & Randomization

75 healthy adults recruited through Scotstoun university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Scotstoun participants provided informed consent and completed health screening questionnaires.

Week 1-2: Scotstoun Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Scotstoun facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Scotstoun Controlled Testing Protocol

Scotstoun innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Scotstoun laboratory.

Week 6-7: Scotstoun Polygraph Comparison Testing

All Scotstoun participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Scotstoun Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Scotstoun study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Scotstoun P300 Recognition Response Analysis

Scotstoun Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Scotstoun Guilty P300 318ms, 11.3μV Scotstoun Innocent P300 315ms, 4.2μV Scotstoun Guilty Knowledge (n=35) Scotstoun Innocent Control (n=40)

Figure 1: Scotstoun grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Scotstoun groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Scotstoun 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Scotstoun guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Scotstoun Statistical Analysis & Performance Metrics

Scotstoun Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Scotstoun Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Scotstoun Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Scotstoun Difference - 7.1 - 6.0 - 8.2 3 ± 42

Scotstoun Statistical Significance Testing:

  • Scotstoun Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Scotstoun Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Scotstoun Effect Size: η² = 0.681 (large effect)
  • Scotstoun Power Analysis: β = 0.999 (excellent statistical power)
  • Scotstoun Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Scotstoun Detection Performance Metrics:

Scotstoun Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Scotstoun 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Scotstoun Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Scotstoun Improvement Ratio +81% +120% +98% +101% Immediate

Scotstoun Post-Test System Validation

Following completion of all Scotstoun participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Scotstoun Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Scotstoun Maximum drift: ±0.03% over 8-week period (Excellent stability)

Scotstoun Recognition Memory Research Key Findings

  • Scotstoun 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Scotstoun guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Scotstoun system calibration remained stable within ±0.03% over 8-week study period
  • Scotstoun response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Scotstoun EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Scotstoun participants
  • Scotstoun pre/post calibration validation confirms measurement reliability and traceability

Scotstoun Discussion & Clinical Implications

This controlled study conducted in Scotstoun demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Scotstoun Clinical Significance:

  • Scotstoun Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Scotstoun Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Scotstoun Response Time: Real-time P300 detection enables immediate assessment
  • Scotstoun Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Scotstoun Quality Assurance: Complete calibration validation ensures measurement integrity
This Scotstoun research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Scotstoun Lead Researcher

Scotstoun Practical Applications:

  • Scotstoun Forensic Psychology: Evidence-based assessment of concealed information
  • Scotstoun Security Screening: Reliable pre-employment and periodic assessments
  • Scotstoun Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Scotstoun Research Applications: Validated tool for memory and recognition studies
  • Scotstoun Clinical Assessment: Objective neurological evaluation with documented accuracy

From Scotstoun Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Scotstoun study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Scotstoun are grounded in published science rather than subjective opinion.

How the Scotstoun Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Scotstoun
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Scotstoun are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Scotstoun P300 Research?

This Scotstoun recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Scotstoun forensic and legal teams: seeking research-backed lie detector evidence
  • Scotstoun clinicians: requiring objective EEG markers for recognition and memory
  • Scotstoun security & compliance departments: interested in advanced screening tools
  • Scotstoun universities & labs: looking to build on validated P300 protocols

Scotstoun Future Research Directions

This foundational Scotstoun research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Scotstoun Planned Studies:

  • Scotstoun Multi-site Validation: Replication across multiple research centers
  • Scotstoun Population Diversity: Performance evaluation across demographic groups
  • Scotstoun Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Scotstoun Complex Scenarios: Real-world application validation studies
  • Scotstoun Machine Learning Integration: AI-enhanced pattern recognition development

Scotstoun P300 Research & Testing Services

Based on the success of this Scotstoun research study, we now offer comprehensive P300 recognition memory testing services throughout the Scotstoun area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Scotstoun Service Features:

  • Scotstoun Professional Testing: Certified EEG technicians serving Scotstoun research community
  • Scotstoun Complete Confidentiality: Strict privacy protection throughout Scotstoun area
  • Scotstoun Same-Day Results: Immediate analysis and reporting for Scotstoun clients
  • Scotstoun Academic Support: Research collaboration and data sharing for Scotstoun institutions
  • Scotstoun Mobile Testing: On-site testing at Scotstoun universities and research facilities
£2999
Scotstoun P300 Research Session
£4999
Scotstoun Full Study Package
£7999
Scotstoun Multi-Session Research
24/7
Scotstoun Research Support
"The Scotstoun P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Scotstoun Cognitive Research Director

Scotstoun Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Scotstoun?

P300 recognition memory research in Scotstoun involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Scotstoun study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Scotstoun research?

Our Scotstoun calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Scotstoun.

What are the key findings of the Scotstoun P300 recognition memory study?

Key findings from Scotstoun include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Scotstoun results show statistical significance and research reproducibility.

Is the Scotstoun research data available for academic use?

Yes, we provide access to anonymized Scotstoun research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Scotstoun P300 recognition memory research support?

Scotstoun applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Scotstoun?

Our Scotstoun validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.