Prestwick Recognition Study September 15, 2024 n=75 Participants (Prestwick) 8-week Prestwick study

Prestwick P300 Recognition Memory Research

Comprehensive controlled study conducted in Prestwick documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Prestwick participants.

Prestwick Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Prestwick

Ethics Approval: Prestwick University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Prestwick facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Prestwick research

Study Period: September 15 - November 10, 2024 (8 weeks) in Prestwick

Prestwick Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Prestwick participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Prestwick participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Prestwick participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Prestwick guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Prestwick testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Prestwick with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Prestwick Participants
95.2%
Prestwick Accuracy
318ms
Prestwick P300 Latency
11.3μV
Prestwick Peak Amplitude

Prestwick Plain-English Summary

In simple terms, this Prestwick study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Prestwick.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Prestwick research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Prestwick, particularly for cases where objective, research-backed evidence is important.

Prestwick Pre-Test System Calibration

All Prestwick testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Prestwick participant testing commenced.

Prestwick Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Prestwick channels within ±0.2% tolerance

Prestwick Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Prestwick parameters within specification limits

Prestwick Research Methodology

Week 1: Prestwick Participant Recruitment & Randomization

75 healthy adults recruited through Prestwick university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Prestwick participants provided informed consent and completed health screening questionnaires.

Week 1-2: Prestwick Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Prestwick facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Prestwick Controlled Testing Protocol

Prestwick innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Prestwick laboratory.

Week 6-7: Prestwick Polygraph Comparison Testing

All Prestwick participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Prestwick Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Prestwick study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Prestwick P300 Recognition Response Analysis

Prestwick Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Prestwick Guilty P300 318ms, 11.3μV Prestwick Innocent P300 315ms, 4.2μV Prestwick Guilty Knowledge (n=35) Prestwick Innocent Control (n=40)

Figure 1: Prestwick grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Prestwick groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Prestwick 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Prestwick guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Prestwick Statistical Analysis & Performance Metrics

Prestwick Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Prestwick Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Prestwick Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Prestwick Difference - 7.1 - 6.0 - 8.2 3 ± 42

Prestwick Statistical Significance Testing:

  • Prestwick Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Prestwick Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Prestwick Effect Size: η² = 0.681 (large effect)
  • Prestwick Power Analysis: β = 0.999 (excellent statistical power)
  • Prestwick Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Prestwick Detection Performance Metrics:

Prestwick Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Prestwick 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Prestwick Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Prestwick Improvement Ratio +81% +120% +98% +101% Immediate

Prestwick Post-Test System Validation

Following completion of all Prestwick participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Prestwick Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Prestwick Maximum drift: ±0.03% over 8-week period (Excellent stability)

Prestwick Recognition Memory Research Key Findings

  • Prestwick 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Prestwick guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Prestwick system calibration remained stable within ±0.03% over 8-week study period
  • Prestwick response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Prestwick EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Prestwick participants
  • Prestwick pre/post calibration validation confirms measurement reliability and traceability

Prestwick Discussion & Clinical Implications

This controlled study conducted in Prestwick demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Prestwick Clinical Significance:

  • Prestwick Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Prestwick Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Prestwick Response Time: Real-time P300 detection enables immediate assessment
  • Prestwick Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Prestwick Quality Assurance: Complete calibration validation ensures measurement integrity
This Prestwick research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Prestwick Lead Researcher

Prestwick Practical Applications:

  • Prestwick Forensic Psychology: Evidence-based assessment of concealed information
  • Prestwick Security Screening: Reliable pre-employment and periodic assessments
  • Prestwick Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Prestwick Research Applications: Validated tool for memory and recognition studies
  • Prestwick Clinical Assessment: Objective neurological evaluation with documented accuracy

From Prestwick Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Prestwick study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Prestwick are grounded in published science rather than subjective opinion.

How the Prestwick Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Prestwick
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Prestwick are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Prestwick P300 Research?

This Prestwick recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Prestwick forensic and legal teams: seeking research-backed lie detector evidence
  • Prestwick clinicians: requiring objective EEG markers for recognition and memory
  • Prestwick security & compliance departments: interested in advanced screening tools
  • Prestwick universities & labs: looking to build on validated P300 protocols

Prestwick Future Research Directions

This foundational Prestwick research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Prestwick Planned Studies:

  • Prestwick Multi-site Validation: Replication across multiple research centers
  • Prestwick Population Diversity: Performance evaluation across demographic groups
  • Prestwick Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Prestwick Complex Scenarios: Real-world application validation studies
  • Prestwick Machine Learning Integration: AI-enhanced pattern recognition development

Prestwick P300 Research & Testing Services

Based on the success of this Prestwick research study, we now offer comprehensive P300 recognition memory testing services throughout the Prestwick area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Prestwick Service Features:

  • Prestwick Professional Testing: Certified EEG technicians serving Prestwick research community
  • Prestwick Complete Confidentiality: Strict privacy protection throughout Prestwick area
  • Prestwick Same-Day Results: Immediate analysis and reporting for Prestwick clients
  • Prestwick Academic Support: Research collaboration and data sharing for Prestwick institutions
  • Prestwick Mobile Testing: On-site testing at Prestwick universities and research facilities
£2999
Prestwick P300 Research Session
£4999
Prestwick Full Study Package
£7999
Prestwick Multi-Session Research
24/7
Prestwick Research Support
"The Prestwick P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Prestwick Cognitive Research Director

Prestwick Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Prestwick?

P300 recognition memory research in Prestwick involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Prestwick study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Prestwick research?

Our Prestwick calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Prestwick.

What are the key findings of the Prestwick P300 recognition memory study?

Key findings from Prestwick include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Prestwick results show statistical significance and research reproducibility.

Is the Prestwick research data available for academic use?

Yes, we provide access to anonymized Prestwick research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Prestwick P300 recognition memory research support?

Prestwick applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Prestwick?

Our Prestwick validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.