Oxton Recognition Study September 15, 2024 n=75 Participants (Oxton) 8-week Oxton study

Oxton P300 Recognition Memory Research

Comprehensive controlled study conducted in Oxton documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Oxton participants.

Oxton Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Oxton

Ethics Approval: Oxton University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Oxton facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Oxton research

Study Period: September 15 - November 10, 2024 (8 weeks) in Oxton

Oxton Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Oxton participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Oxton participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Oxton participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Oxton guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Oxton testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Oxton with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Oxton Participants
95.2%
Oxton Accuracy
318ms
Oxton P300 Latency
11.3μV
Oxton Peak Amplitude

Oxton Plain-English Summary

In simple terms, this Oxton study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Oxton.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Oxton research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Oxton, particularly for cases where objective, research-backed evidence is important.

Oxton Pre-Test System Calibration

All Oxton testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Oxton participant testing commenced.

Oxton Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Oxton channels within ±0.2% tolerance

Oxton Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Oxton parameters within specification limits

Oxton Research Methodology

Week 1: Oxton Participant Recruitment & Randomization

75 healthy adults recruited through Oxton university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Oxton participants provided informed consent and completed health screening questionnaires.

Week 1-2: Oxton Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Oxton facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Oxton Controlled Testing Protocol

Oxton innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Oxton laboratory.

Week 6-7: Oxton Polygraph Comparison Testing

All Oxton participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Oxton Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Oxton study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Oxton P300 Recognition Response Analysis

Oxton Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Oxton Guilty P300 318ms, 11.3μV Oxton Innocent P300 315ms, 4.2μV Oxton Guilty Knowledge (n=35) Oxton Innocent Control (n=40)

Figure 1: Oxton grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Oxton groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Oxton 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Oxton guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Oxton Statistical Analysis & Performance Metrics

Oxton Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Oxton Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Oxton Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Oxton Difference - 7.1 - 6.0 - 8.2 3 ± 42

Oxton Statistical Significance Testing:

  • Oxton Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Oxton Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Oxton Effect Size: η² = 0.681 (large effect)
  • Oxton Power Analysis: β = 0.999 (excellent statistical power)
  • Oxton Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Oxton Detection Performance Metrics:

Oxton Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Oxton 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Oxton Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Oxton Improvement Ratio +81% +120% +98% +101% Immediate

Oxton Post-Test System Validation

Following completion of all Oxton participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Oxton Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Oxton Maximum drift: ±0.03% over 8-week period (Excellent stability)

Oxton Recognition Memory Research Key Findings

  • Oxton 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Oxton guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Oxton system calibration remained stable within ±0.03% over 8-week study period
  • Oxton response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Oxton EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Oxton participants
  • Oxton pre/post calibration validation confirms measurement reliability and traceability

Oxton Discussion & Clinical Implications

This controlled study conducted in Oxton demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Oxton Clinical Significance:

  • Oxton Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Oxton Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Oxton Response Time: Real-time P300 detection enables immediate assessment
  • Oxton Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Oxton Quality Assurance: Complete calibration validation ensures measurement integrity
This Oxton research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Oxton Lead Researcher

Oxton Practical Applications:

  • Oxton Forensic Psychology: Evidence-based assessment of concealed information
  • Oxton Security Screening: Reliable pre-employment and periodic assessments
  • Oxton Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Oxton Research Applications: Validated tool for memory and recognition studies
  • Oxton Clinical Assessment: Objective neurological evaluation with documented accuracy

From Oxton Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Oxton study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Oxton are grounded in published science rather than subjective opinion.

How the Oxton Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Oxton
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Oxton are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Oxton P300 Research?

This Oxton recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Oxton forensic and legal teams: seeking research-backed lie detector evidence
  • Oxton clinicians: requiring objective EEG markers for recognition and memory
  • Oxton security & compliance departments: interested in advanced screening tools
  • Oxton universities & labs: looking to build on validated P300 protocols

Oxton Future Research Directions

This foundational Oxton research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Oxton Planned Studies:

  • Oxton Multi-site Validation: Replication across multiple research centers
  • Oxton Population Diversity: Performance evaluation across demographic groups
  • Oxton Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Oxton Complex Scenarios: Real-world application validation studies
  • Oxton Machine Learning Integration: AI-enhanced pattern recognition development

Oxton P300 Research & Testing Services

Based on the success of this Oxton research study, we now offer comprehensive P300 recognition memory testing services throughout the Oxton area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Oxton Service Features:

  • Oxton Professional Testing: Certified EEG technicians serving Oxton research community
  • Oxton Complete Confidentiality: Strict privacy protection throughout Oxton area
  • Oxton Same-Day Results: Immediate analysis and reporting for Oxton clients
  • Oxton Academic Support: Research collaboration and data sharing for Oxton institutions
  • Oxton Mobile Testing: On-site testing at Oxton universities and research facilities
£2999
Oxton P300 Research Session
£4999
Oxton Full Study Package
£7999
Oxton Multi-Session Research
24/7
Oxton Research Support
"The Oxton P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Oxton Cognitive Research Director

Oxton Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Oxton?

P300 recognition memory research in Oxton involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Oxton study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Oxton research?

Our Oxton calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Oxton.

What are the key findings of the Oxton P300 recognition memory study?

Key findings from Oxton include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Oxton results show statistical significance and research reproducibility.

Is the Oxton research data available for academic use?

Yes, we provide access to anonymized Oxton research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Oxton P300 recognition memory research support?

Oxton applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Oxton?

Our Oxton validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.