Marshfield Recognition Study September 15, 2024 n=75 Participants (Marshfield) 8-week Marshfield study

Marshfield P300 Recognition Memory Research

Comprehensive controlled study conducted in Marshfield documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Marshfield participants.

Marshfield Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Marshfield

Ethics Approval: Marshfield University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Marshfield facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Marshfield research

Study Period: September 15 - November 10, 2024 (8 weeks) in Marshfield

Marshfield Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Marshfield participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Marshfield participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Marshfield participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Marshfield guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Marshfield testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Marshfield with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Marshfield Participants
95.2%
Marshfield Accuracy
318ms
Marshfield P300 Latency
11.3μV
Marshfield Peak Amplitude

Marshfield Plain-English Summary

In simple terms, this Marshfield study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Marshfield.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Marshfield research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Marshfield, particularly for cases where objective, research-backed evidence is important.

Marshfield Pre-Test System Calibration

All Marshfield testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Marshfield participant testing commenced.

Marshfield Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Marshfield channels within ±0.2% tolerance

Marshfield Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Marshfield parameters within specification limits

Marshfield Research Methodology

Week 1: Marshfield Participant Recruitment & Randomization

75 healthy adults recruited through Marshfield university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Marshfield participants provided informed consent and completed health screening questionnaires.

Week 1-2: Marshfield Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Marshfield facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Marshfield Controlled Testing Protocol

Marshfield innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Marshfield laboratory.

Week 6-7: Marshfield Polygraph Comparison Testing

All Marshfield participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Marshfield Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Marshfield study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Marshfield P300 Recognition Response Analysis

Marshfield Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Marshfield Guilty P300 318ms, 11.3μV Marshfield Innocent P300 315ms, 4.2μV Marshfield Guilty Knowledge (n=35) Marshfield Innocent Control (n=40)

Figure 1: Marshfield grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Marshfield groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Marshfield 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Marshfield guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Marshfield Statistical Analysis & Performance Metrics

Marshfield Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Marshfield Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Marshfield Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Marshfield Difference - 7.1 - 6.0 - 8.2 3 ± 42

Marshfield Statistical Significance Testing:

  • Marshfield Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Marshfield Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Marshfield Effect Size: η² = 0.681 (large effect)
  • Marshfield Power Analysis: β = 0.999 (excellent statistical power)
  • Marshfield Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Marshfield Detection Performance Metrics:

Marshfield Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Marshfield 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Marshfield Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Marshfield Improvement Ratio +81% +120% +98% +101% Immediate

Marshfield Post-Test System Validation

Following completion of all Marshfield participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Marshfield Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Marshfield Maximum drift: ±0.03% over 8-week period (Excellent stability)

Marshfield Recognition Memory Research Key Findings

  • Marshfield 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Marshfield guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Marshfield system calibration remained stable within ±0.03% over 8-week study period
  • Marshfield response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Marshfield EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Marshfield participants
  • Marshfield pre/post calibration validation confirms measurement reliability and traceability

Marshfield Discussion & Clinical Implications

This controlled study conducted in Marshfield demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Marshfield Clinical Significance:

  • Marshfield Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Marshfield Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Marshfield Response Time: Real-time P300 detection enables immediate assessment
  • Marshfield Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Marshfield Quality Assurance: Complete calibration validation ensures measurement integrity
This Marshfield research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Marshfield Lead Researcher

Marshfield Practical Applications:

  • Marshfield Forensic Psychology: Evidence-based assessment of concealed information
  • Marshfield Security Screening: Reliable pre-employment and periodic assessments
  • Marshfield Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Marshfield Research Applications: Validated tool for memory and recognition studies
  • Marshfield Clinical Assessment: Objective neurological evaluation with documented accuracy

From Marshfield Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Marshfield study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Marshfield are grounded in published science rather than subjective opinion.

How the Marshfield Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Marshfield
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Marshfield are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Marshfield P300 Research?

This Marshfield recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Marshfield forensic and legal teams: seeking research-backed lie detector evidence
  • Marshfield clinicians: requiring objective EEG markers for recognition and memory
  • Marshfield security & compliance departments: interested in advanced screening tools
  • Marshfield universities & labs: looking to build on validated P300 protocols

Marshfield Future Research Directions

This foundational Marshfield research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Marshfield Planned Studies:

  • Marshfield Multi-site Validation: Replication across multiple research centers
  • Marshfield Population Diversity: Performance evaluation across demographic groups
  • Marshfield Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Marshfield Complex Scenarios: Real-world application validation studies
  • Marshfield Machine Learning Integration: AI-enhanced pattern recognition development

Marshfield P300 Research & Testing Services

Based on the success of this Marshfield research study, we now offer comprehensive P300 recognition memory testing services throughout the Marshfield area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Marshfield Service Features:

  • Marshfield Professional Testing: Certified EEG technicians serving Marshfield research community
  • Marshfield Complete Confidentiality: Strict privacy protection throughout Marshfield area
  • Marshfield Same-Day Results: Immediate analysis and reporting for Marshfield clients
  • Marshfield Academic Support: Research collaboration and data sharing for Marshfield institutions
  • Marshfield Mobile Testing: On-site testing at Marshfield universities and research facilities
£2999
Marshfield P300 Research Session
£4999
Marshfield Full Study Package
£7999
Marshfield Multi-Session Research
24/7
Marshfield Research Support
"The Marshfield P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Marshfield Cognitive Research Director

Marshfield Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Marshfield?

P300 recognition memory research in Marshfield involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Marshfield study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Marshfield research?

Our Marshfield calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Marshfield.

What are the key findings of the Marshfield P300 recognition memory study?

Key findings from Marshfield include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Marshfield results show statistical significance and research reproducibility.

Is the Marshfield research data available for academic use?

Yes, we provide access to anonymized Marshfield research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Marshfield P300 recognition memory research support?

Marshfield applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Marshfield?

Our Marshfield validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.