Llanidloes Recognition Study September 15, 2024 n=75 Participants (Llanidloes) 8-week Llanidloes study

Llanidloes P300 Recognition Memory Research

Comprehensive controlled study conducted in Llanidloes documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Llanidloes participants.

Llanidloes Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Llanidloes

Ethics Approval: Llanidloes University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Llanidloes facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Llanidloes research

Study Period: September 15 - November 10, 2024 (8 weeks) in Llanidloes

Llanidloes Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Llanidloes participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Llanidloes participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Llanidloes participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Llanidloes guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Llanidloes testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Llanidloes with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Llanidloes Participants
95.2%
Llanidloes Accuracy
318ms
Llanidloes P300 Latency
11.3μV
Llanidloes Peak Amplitude

Llanidloes Plain-English Summary

In simple terms, this Llanidloes study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Llanidloes.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Llanidloes research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Llanidloes, particularly for cases where objective, research-backed evidence is important.

Llanidloes Pre-Test System Calibration

All Llanidloes testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Llanidloes participant testing commenced.

Llanidloes Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Llanidloes channels within ±0.2% tolerance

Llanidloes Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Llanidloes parameters within specification limits

Llanidloes Research Methodology

Week 1: Llanidloes Participant Recruitment & Randomization

75 healthy adults recruited through Llanidloes university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Llanidloes participants provided informed consent and completed health screening questionnaires.

Week 1-2: Llanidloes Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Llanidloes facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Llanidloes Controlled Testing Protocol

Llanidloes innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Llanidloes laboratory.

Week 6-7: Llanidloes Polygraph Comparison Testing

All Llanidloes participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Llanidloes Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Llanidloes study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Llanidloes P300 Recognition Response Analysis

Llanidloes Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Llanidloes Guilty P300 318ms, 11.3μV Llanidloes Innocent P300 315ms, 4.2μV Llanidloes Guilty Knowledge (n=35) Llanidloes Innocent Control (n=40)

Figure 1: Llanidloes grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Llanidloes groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Llanidloes 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Llanidloes guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Llanidloes Statistical Analysis & Performance Metrics

Llanidloes Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Llanidloes Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Llanidloes Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Llanidloes Difference - 7.1 - 6.0 - 8.2 3 ± 42

Llanidloes Statistical Significance Testing:

  • Llanidloes Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Llanidloes Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Llanidloes Effect Size: η² = 0.681 (large effect)
  • Llanidloes Power Analysis: β = 0.999 (excellent statistical power)
  • Llanidloes Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Llanidloes Detection Performance Metrics:

Llanidloes Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Llanidloes 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Llanidloes Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Llanidloes Improvement Ratio +81% +120% +98% +101% Immediate

Llanidloes Post-Test System Validation

Following completion of all Llanidloes participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Llanidloes Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Llanidloes Maximum drift: ±0.03% over 8-week period (Excellent stability)

Llanidloes Recognition Memory Research Key Findings

  • Llanidloes 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Llanidloes guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Llanidloes system calibration remained stable within ±0.03% over 8-week study period
  • Llanidloes response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Llanidloes EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Llanidloes participants
  • Llanidloes pre/post calibration validation confirms measurement reliability and traceability

Llanidloes Discussion & Clinical Implications

This controlled study conducted in Llanidloes demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Llanidloes Clinical Significance:

  • Llanidloes Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Llanidloes Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Llanidloes Response Time: Real-time P300 detection enables immediate assessment
  • Llanidloes Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Llanidloes Quality Assurance: Complete calibration validation ensures measurement integrity
This Llanidloes research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Llanidloes Lead Researcher

Llanidloes Practical Applications:

  • Llanidloes Forensic Psychology: Evidence-based assessment of concealed information
  • Llanidloes Security Screening: Reliable pre-employment and periodic assessments
  • Llanidloes Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Llanidloes Research Applications: Validated tool for memory and recognition studies
  • Llanidloes Clinical Assessment: Objective neurological evaluation with documented accuracy

From Llanidloes Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Llanidloes study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Llanidloes are grounded in published science rather than subjective opinion.

How the Llanidloes Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Llanidloes
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Llanidloes are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Llanidloes P300 Research?

This Llanidloes recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Llanidloes forensic and legal teams: seeking research-backed lie detector evidence
  • Llanidloes clinicians: requiring objective EEG markers for recognition and memory
  • Llanidloes security & compliance departments: interested in advanced screening tools
  • Llanidloes universities & labs: looking to build on validated P300 protocols

Llanidloes Future Research Directions

This foundational Llanidloes research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Llanidloes Planned Studies:

  • Llanidloes Multi-site Validation: Replication across multiple research centers
  • Llanidloes Population Diversity: Performance evaluation across demographic groups
  • Llanidloes Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Llanidloes Complex Scenarios: Real-world application validation studies
  • Llanidloes Machine Learning Integration: AI-enhanced pattern recognition development

Llanidloes P300 Research & Testing Services

Based on the success of this Llanidloes research study, we now offer comprehensive P300 recognition memory testing services throughout the Llanidloes area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Llanidloes Service Features:

  • Llanidloes Professional Testing: Certified EEG technicians serving Llanidloes research community
  • Llanidloes Complete Confidentiality: Strict privacy protection throughout Llanidloes area
  • Llanidloes Same-Day Results: Immediate analysis and reporting for Llanidloes clients
  • Llanidloes Academic Support: Research collaboration and data sharing for Llanidloes institutions
  • Llanidloes Mobile Testing: On-site testing at Llanidloes universities and research facilities
£2999
Llanidloes P300 Research Session
£4999
Llanidloes Full Study Package
£7999
Llanidloes Multi-Session Research
24/7
Llanidloes Research Support
"The Llanidloes P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Llanidloes Cognitive Research Director

Llanidloes Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Llanidloes?

P300 recognition memory research in Llanidloes involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Llanidloes study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Llanidloes research?

Our Llanidloes calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Llanidloes.

What are the key findings of the Llanidloes P300 recognition memory study?

Key findings from Llanidloes include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Llanidloes results show statistical significance and research reproducibility.

Is the Llanidloes research data available for academic use?

Yes, we provide access to anonymized Llanidloes research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Llanidloes P300 recognition memory research support?

Llanidloes applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Llanidloes?

Our Llanidloes validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.