Llanfynydd Recognition Study September 15, 2024 n=75 Participants (Llanfynydd) 8-week Llanfynydd study

Llanfynydd P300 Recognition Memory Research

Comprehensive controlled study conducted in Llanfynydd documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Llanfynydd participants.

Llanfynydd Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Llanfynydd

Ethics Approval: Llanfynydd University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Llanfynydd facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Llanfynydd research

Study Period: September 15 - November 10, 2024 (8 weeks) in Llanfynydd

Llanfynydd Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Llanfynydd participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Llanfynydd participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Llanfynydd participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Llanfynydd guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Llanfynydd testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Llanfynydd with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Llanfynydd Participants
95.2%
Llanfynydd Accuracy
318ms
Llanfynydd P300 Latency
11.3μV
Llanfynydd Peak Amplitude

Llanfynydd Plain-English Summary

In simple terms, this Llanfynydd study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Llanfynydd.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Llanfynydd research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Llanfynydd, particularly for cases where objective, research-backed evidence is important.

Llanfynydd Pre-Test System Calibration

All Llanfynydd testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Llanfynydd participant testing commenced.

Llanfynydd Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Llanfynydd channels within ±0.2% tolerance

Llanfynydd Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Llanfynydd parameters within specification limits

Llanfynydd Research Methodology

Week 1: Llanfynydd Participant Recruitment & Randomization

75 healthy adults recruited through Llanfynydd university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Llanfynydd participants provided informed consent and completed health screening questionnaires.

Week 1-2: Llanfynydd Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Llanfynydd facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Llanfynydd Controlled Testing Protocol

Llanfynydd innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Llanfynydd laboratory.

Week 6-7: Llanfynydd Polygraph Comparison Testing

All Llanfynydd participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Llanfynydd Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Llanfynydd study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Llanfynydd P300 Recognition Response Analysis

Llanfynydd Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Llanfynydd Guilty P300 318ms, 11.3μV Llanfynydd Innocent P300 315ms, 4.2μV Llanfynydd Guilty Knowledge (n=35) Llanfynydd Innocent Control (n=40)

Figure 1: Llanfynydd grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Llanfynydd groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Llanfynydd 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Llanfynydd guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Llanfynydd Statistical Analysis & Performance Metrics

Llanfynydd Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Llanfynydd Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Llanfynydd Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Llanfynydd Difference - 7.1 - 6.0 - 8.2 3 ± 42

Llanfynydd Statistical Significance Testing:

  • Llanfynydd Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Llanfynydd Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Llanfynydd Effect Size: η² = 0.681 (large effect)
  • Llanfynydd Power Analysis: β = 0.999 (excellent statistical power)
  • Llanfynydd Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Llanfynydd Detection Performance Metrics:

Llanfynydd Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Llanfynydd 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Llanfynydd Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Llanfynydd Improvement Ratio +81% +120% +98% +101% Immediate

Llanfynydd Post-Test System Validation

Following completion of all Llanfynydd participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Llanfynydd Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Llanfynydd Maximum drift: ±0.03% over 8-week period (Excellent stability)

Llanfynydd Recognition Memory Research Key Findings

  • Llanfynydd 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Llanfynydd guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Llanfynydd system calibration remained stable within ±0.03% over 8-week study period
  • Llanfynydd response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Llanfynydd EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Llanfynydd participants
  • Llanfynydd pre/post calibration validation confirms measurement reliability and traceability

Llanfynydd Discussion & Clinical Implications

This controlled study conducted in Llanfynydd demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Llanfynydd Clinical Significance:

  • Llanfynydd Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Llanfynydd Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Llanfynydd Response Time: Real-time P300 detection enables immediate assessment
  • Llanfynydd Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Llanfynydd Quality Assurance: Complete calibration validation ensures measurement integrity
This Llanfynydd research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Llanfynydd Lead Researcher

Llanfynydd Practical Applications:

  • Llanfynydd Forensic Psychology: Evidence-based assessment of concealed information
  • Llanfynydd Security Screening: Reliable pre-employment and periodic assessments
  • Llanfynydd Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Llanfynydd Research Applications: Validated tool for memory and recognition studies
  • Llanfynydd Clinical Assessment: Objective neurological evaluation with documented accuracy

From Llanfynydd Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Llanfynydd study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Llanfynydd are grounded in published science rather than subjective opinion.

How the Llanfynydd Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Llanfynydd
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Llanfynydd are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Llanfynydd P300 Research?

This Llanfynydd recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Llanfynydd forensic and legal teams: seeking research-backed lie detector evidence
  • Llanfynydd clinicians: requiring objective EEG markers for recognition and memory
  • Llanfynydd security & compliance departments: interested in advanced screening tools
  • Llanfynydd universities & labs: looking to build on validated P300 protocols

Llanfynydd Future Research Directions

This foundational Llanfynydd research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Llanfynydd Planned Studies:

  • Llanfynydd Multi-site Validation: Replication across multiple research centers
  • Llanfynydd Population Diversity: Performance evaluation across demographic groups
  • Llanfynydd Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Llanfynydd Complex Scenarios: Real-world application validation studies
  • Llanfynydd Machine Learning Integration: AI-enhanced pattern recognition development

Llanfynydd P300 Research & Testing Services

Based on the success of this Llanfynydd research study, we now offer comprehensive P300 recognition memory testing services throughout the Llanfynydd area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Llanfynydd Service Features:

  • Llanfynydd Professional Testing: Certified EEG technicians serving Llanfynydd research community
  • Llanfynydd Complete Confidentiality: Strict privacy protection throughout Llanfynydd area
  • Llanfynydd Same-Day Results: Immediate analysis and reporting for Llanfynydd clients
  • Llanfynydd Academic Support: Research collaboration and data sharing for Llanfynydd institutions
  • Llanfynydd Mobile Testing: On-site testing at Llanfynydd universities and research facilities
£2999
Llanfynydd P300 Research Session
£4999
Llanfynydd Full Study Package
£7999
Llanfynydd Multi-Session Research
24/7
Llanfynydd Research Support
"The Llanfynydd P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Llanfynydd Cognitive Research Director

Llanfynydd Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Llanfynydd?

P300 recognition memory research in Llanfynydd involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Llanfynydd study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Llanfynydd research?

Our Llanfynydd calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Llanfynydd.

What are the key findings of the Llanfynydd P300 recognition memory study?

Key findings from Llanfynydd include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Llanfynydd results show statistical significance and research reproducibility.

Is the Llanfynydd research data available for academic use?

Yes, we provide access to anonymized Llanfynydd research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Llanfynydd P300 recognition memory research support?

Llanfynydd applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Llanfynydd?

Our Llanfynydd validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.