Kilsyth Recognition Study September 15, 2024 n=75 Participants (Kilsyth) 8-week Kilsyth study

Kilsyth P300 Recognition Memory Research

Comprehensive controlled study conducted in Kilsyth documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Kilsyth participants.

Kilsyth Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Kilsyth

Ethics Approval: Kilsyth University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Kilsyth facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Kilsyth research

Study Period: September 15 - November 10, 2024 (8 weeks) in Kilsyth

Kilsyth Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Kilsyth participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Kilsyth participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Kilsyth participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Kilsyth guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Kilsyth testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Kilsyth with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Kilsyth Participants
95.2%
Kilsyth Accuracy
318ms
Kilsyth P300 Latency
11.3μV
Kilsyth Peak Amplitude

Kilsyth Plain-English Summary

In simple terms, this Kilsyth study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Kilsyth.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Kilsyth research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Kilsyth, particularly for cases where objective, research-backed evidence is important.

Kilsyth Pre-Test System Calibration

All Kilsyth testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Kilsyth participant testing commenced.

Kilsyth Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Kilsyth channels within ±0.2% tolerance

Kilsyth Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Kilsyth parameters within specification limits

Kilsyth Research Methodology

Week 1: Kilsyth Participant Recruitment & Randomization

75 healthy adults recruited through Kilsyth university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Kilsyth participants provided informed consent and completed health screening questionnaires.

Week 1-2: Kilsyth Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Kilsyth facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Kilsyth Controlled Testing Protocol

Kilsyth innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Kilsyth laboratory.

Week 6-7: Kilsyth Polygraph Comparison Testing

All Kilsyth participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Kilsyth Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Kilsyth study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Kilsyth P300 Recognition Response Analysis

Kilsyth Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Kilsyth Guilty P300 318ms, 11.3μV Kilsyth Innocent P300 315ms, 4.2μV Kilsyth Guilty Knowledge (n=35) Kilsyth Innocent Control (n=40)

Figure 1: Kilsyth grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Kilsyth groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Kilsyth 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Kilsyth guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Kilsyth Statistical Analysis & Performance Metrics

Kilsyth Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Kilsyth Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Kilsyth Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Kilsyth Difference - 7.1 - 6.0 - 8.2 3 ± 42

Kilsyth Statistical Significance Testing:

  • Kilsyth Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Kilsyth Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Kilsyth Effect Size: η² = 0.681 (large effect)
  • Kilsyth Power Analysis: β = 0.999 (excellent statistical power)
  • Kilsyth Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Kilsyth Detection Performance Metrics:

Kilsyth Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Kilsyth 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Kilsyth Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Kilsyth Improvement Ratio +81% +120% +98% +101% Immediate

Kilsyth Post-Test System Validation

Following completion of all Kilsyth participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Kilsyth Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Kilsyth Maximum drift: ±0.03% over 8-week period (Excellent stability)

Kilsyth Recognition Memory Research Key Findings

  • Kilsyth 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Kilsyth guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Kilsyth system calibration remained stable within ±0.03% over 8-week study period
  • Kilsyth response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Kilsyth EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Kilsyth participants
  • Kilsyth pre/post calibration validation confirms measurement reliability and traceability

Kilsyth Discussion & Clinical Implications

This controlled study conducted in Kilsyth demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Kilsyth Clinical Significance:

  • Kilsyth Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Kilsyth Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Kilsyth Response Time: Real-time P300 detection enables immediate assessment
  • Kilsyth Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Kilsyth Quality Assurance: Complete calibration validation ensures measurement integrity
This Kilsyth research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Kilsyth Lead Researcher

Kilsyth Practical Applications:

  • Kilsyth Forensic Psychology: Evidence-based assessment of concealed information
  • Kilsyth Security Screening: Reliable pre-employment and periodic assessments
  • Kilsyth Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Kilsyth Research Applications: Validated tool for memory and recognition studies
  • Kilsyth Clinical Assessment: Objective neurological evaluation with documented accuracy

From Kilsyth Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Kilsyth study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Kilsyth are grounded in published science rather than subjective opinion.

How the Kilsyth Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Kilsyth
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Kilsyth are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Kilsyth P300 Research?

This Kilsyth recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Kilsyth forensic and legal teams: seeking research-backed lie detector evidence
  • Kilsyth clinicians: requiring objective EEG markers for recognition and memory
  • Kilsyth security & compliance departments: interested in advanced screening tools
  • Kilsyth universities & labs: looking to build on validated P300 protocols

Kilsyth Future Research Directions

This foundational Kilsyth research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Kilsyth Planned Studies:

  • Kilsyth Multi-site Validation: Replication across multiple research centers
  • Kilsyth Population Diversity: Performance evaluation across demographic groups
  • Kilsyth Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Kilsyth Complex Scenarios: Real-world application validation studies
  • Kilsyth Machine Learning Integration: AI-enhanced pattern recognition development

Kilsyth P300 Research & Testing Services

Based on the success of this Kilsyth research study, we now offer comprehensive P300 recognition memory testing services throughout the Kilsyth area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Kilsyth Service Features:

  • Kilsyth Professional Testing: Certified EEG technicians serving Kilsyth research community
  • Kilsyth Complete Confidentiality: Strict privacy protection throughout Kilsyth area
  • Kilsyth Same-Day Results: Immediate analysis and reporting for Kilsyth clients
  • Kilsyth Academic Support: Research collaboration and data sharing for Kilsyth institutions
  • Kilsyth Mobile Testing: On-site testing at Kilsyth universities and research facilities
£2999
Kilsyth P300 Research Session
£4999
Kilsyth Full Study Package
£7999
Kilsyth Multi-Session Research
24/7
Kilsyth Research Support
"The Kilsyth P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Kilsyth Cognitive Research Director

Kilsyth Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Kilsyth?

P300 recognition memory research in Kilsyth involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Kilsyth study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Kilsyth research?

Our Kilsyth calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Kilsyth.

What are the key findings of the Kilsyth P300 recognition memory study?

Key findings from Kilsyth include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Kilsyth results show statistical significance and research reproducibility.

Is the Kilsyth research data available for academic use?

Yes, we provide access to anonymized Kilsyth research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Kilsyth P300 recognition memory research support?

Kilsyth applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Kilsyth?

Our Kilsyth validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.