Kelly Recognition Study September 15, 2024 n=75 Participants (Kelly) 8-week Kelly study

Kelly P300 Recognition Memory Research

Comprehensive controlled study conducted in Kelly documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Kelly participants.

Kelly Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Kelly

Ethics Approval: Kelly University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Kelly facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Kelly research

Study Period: September 15 - November 10, 2024 (8 weeks) in Kelly

Kelly Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Kelly participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Kelly participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Kelly participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Kelly guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Kelly testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Kelly with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Kelly Participants
95.2%
Kelly Accuracy
318ms
Kelly P300 Latency
11.3μV
Kelly Peak Amplitude

Kelly Plain-English Summary

In simple terms, this Kelly study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Kelly.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Kelly research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Kelly, particularly for cases where objective, research-backed evidence is important.

Kelly Pre-Test System Calibration

All Kelly testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Kelly participant testing commenced.

Kelly Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Kelly channels within ±0.2% tolerance

Kelly Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Kelly parameters within specification limits

Kelly Research Methodology

Week 1: Kelly Participant Recruitment & Randomization

75 healthy adults recruited through Kelly university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Kelly participants provided informed consent and completed health screening questionnaires.

Week 1-2: Kelly Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Kelly facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Kelly Controlled Testing Protocol

Kelly innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Kelly laboratory.

Week 6-7: Kelly Polygraph Comparison Testing

All Kelly participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Kelly Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Kelly study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Kelly P300 Recognition Response Analysis

Kelly Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Kelly Guilty P300 318ms, 11.3μV Kelly Innocent P300 315ms, 4.2μV Kelly Guilty Knowledge (n=35) Kelly Innocent Control (n=40)

Figure 1: Kelly grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Kelly groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Kelly 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Kelly guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Kelly Statistical Analysis & Performance Metrics

Kelly Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Kelly Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Kelly Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Kelly Difference - 7.1 - 6.0 - 8.2 3 ± 42

Kelly Statistical Significance Testing:

  • Kelly Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Kelly Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Kelly Effect Size: η² = 0.681 (large effect)
  • Kelly Power Analysis: β = 0.999 (excellent statistical power)
  • Kelly Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Kelly Detection Performance Metrics:

Kelly Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Kelly 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Kelly Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Kelly Improvement Ratio +81% +120% +98% +101% Immediate

Kelly Post-Test System Validation

Following completion of all Kelly participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Kelly Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Kelly Maximum drift: ±0.03% over 8-week period (Excellent stability)

Kelly Recognition Memory Research Key Findings

  • Kelly 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Kelly guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Kelly system calibration remained stable within ±0.03% over 8-week study period
  • Kelly response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Kelly EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Kelly participants
  • Kelly pre/post calibration validation confirms measurement reliability and traceability

Kelly Discussion & Clinical Implications

This controlled study conducted in Kelly demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Kelly Clinical Significance:

  • Kelly Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Kelly Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Kelly Response Time: Real-time P300 detection enables immediate assessment
  • Kelly Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Kelly Quality Assurance: Complete calibration validation ensures measurement integrity
This Kelly research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Kelly Lead Researcher

Kelly Practical Applications:

  • Kelly Forensic Psychology: Evidence-based assessment of concealed information
  • Kelly Security Screening: Reliable pre-employment and periodic assessments
  • Kelly Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Kelly Research Applications: Validated tool for memory and recognition studies
  • Kelly Clinical Assessment: Objective neurological evaluation with documented accuracy

From Kelly Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Kelly study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Kelly are grounded in published science rather than subjective opinion.

How the Kelly Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Kelly
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Kelly are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Kelly P300 Research?

This Kelly recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Kelly forensic and legal teams: seeking research-backed lie detector evidence
  • Kelly clinicians: requiring objective EEG markers for recognition and memory
  • Kelly security & compliance departments: interested in advanced screening tools
  • Kelly universities & labs: looking to build on validated P300 protocols

Kelly Future Research Directions

This foundational Kelly research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Kelly Planned Studies:

  • Kelly Multi-site Validation: Replication across multiple research centers
  • Kelly Population Diversity: Performance evaluation across demographic groups
  • Kelly Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Kelly Complex Scenarios: Real-world application validation studies
  • Kelly Machine Learning Integration: AI-enhanced pattern recognition development

Kelly P300 Research & Testing Services

Based on the success of this Kelly research study, we now offer comprehensive P300 recognition memory testing services throughout the Kelly area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Kelly Service Features:

  • Kelly Professional Testing: Certified EEG technicians serving Kelly research community
  • Kelly Complete Confidentiality: Strict privacy protection throughout Kelly area
  • Kelly Same-Day Results: Immediate analysis and reporting for Kelly clients
  • Kelly Academic Support: Research collaboration and data sharing for Kelly institutions
  • Kelly Mobile Testing: On-site testing at Kelly universities and research facilities
£2999
Kelly P300 Research Session
£4999
Kelly Full Study Package
£7999
Kelly Multi-Session Research
24/7
Kelly Research Support
"The Kelly P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Kelly Cognitive Research Director

Kelly Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Kelly?

P300 recognition memory research in Kelly involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Kelly study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Kelly research?

Our Kelly calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Kelly.

What are the key findings of the Kelly P300 recognition memory study?

Key findings from Kelly include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Kelly results show statistical significance and research reproducibility.

Is the Kelly research data available for academic use?

Yes, we provide access to anonymized Kelly research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Kelly P300 recognition memory research support?

Kelly applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Kelly?

Our Kelly validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.