Heriot Row Recognition Study September 15, 2024 n=75 Participants (Heriot Row) 8-week Heriot Row study

Heriot Row P300 Recognition Memory Research

Comprehensive controlled study conducted in Heriot Row documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Heriot Row participants.

Heriot Row Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Heriot Row

Ethics Approval: Heriot Row University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Heriot Row facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Heriot Row research

Study Period: September 15 - November 10, 2024 (8 weeks) in Heriot Row

Heriot Row Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Heriot Row participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Heriot Row participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Heriot Row participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Heriot Row guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Heriot Row testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Heriot Row with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Heriot Row Participants
95.2%
Heriot Row Accuracy
318ms
Heriot Row P300 Latency
11.3μV
Heriot Row Peak Amplitude

Heriot Row Plain-English Summary

In simple terms, this Heriot Row study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Heriot Row.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Heriot Row research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Heriot Row, particularly for cases where objective, research-backed evidence is important.

Heriot Row Pre-Test System Calibration

All Heriot Row testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Heriot Row participant testing commenced.

Heriot Row Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Heriot Row channels within ±0.2% tolerance

Heriot Row Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Heriot Row parameters within specification limits

Heriot Row Research Methodology

Week 1: Heriot Row Participant Recruitment & Randomization

75 healthy adults recruited through Heriot Row university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Heriot Row participants provided informed consent and completed health screening questionnaires.

Week 1-2: Heriot Row Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Heriot Row facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Heriot Row Controlled Testing Protocol

Heriot Row innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Heriot Row laboratory.

Week 6-7: Heriot Row Polygraph Comparison Testing

All Heriot Row participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Heriot Row Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Heriot Row study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Heriot Row P300 Recognition Response Analysis

Heriot Row Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Heriot Row Guilty P300 318ms, 11.3μV Heriot Row Innocent P300 315ms, 4.2μV Heriot Row Guilty Knowledge (n=35) Heriot Row Innocent Control (n=40)

Figure 1: Heriot Row grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Heriot Row groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Heriot Row 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Heriot Row guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Heriot Row Statistical Analysis & Performance Metrics

Heriot Row Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Heriot Row Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Heriot Row Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Heriot Row Difference - 7.1 - 6.0 - 8.2 3 ± 42

Heriot Row Statistical Significance Testing:

  • Heriot Row Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Heriot Row Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Heriot Row Effect Size: η² = 0.681 (large effect)
  • Heriot Row Power Analysis: β = 0.999 (excellent statistical power)
  • Heriot Row Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Heriot Row Detection Performance Metrics:

Heriot Row Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Heriot Row 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Heriot Row Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Heriot Row Improvement Ratio +81% +120% +98% +101% Immediate

Heriot Row Post-Test System Validation

Following completion of all Heriot Row participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Heriot Row Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Heriot Row Maximum drift: ±0.03% over 8-week period (Excellent stability)

Heriot Row Recognition Memory Research Key Findings

  • Heriot Row 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Heriot Row guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Heriot Row system calibration remained stable within ±0.03% over 8-week study period
  • Heriot Row response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Heriot Row EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Heriot Row participants
  • Heriot Row pre/post calibration validation confirms measurement reliability and traceability

Heriot Row Discussion & Clinical Implications

This controlled study conducted in Heriot Row demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Heriot Row Clinical Significance:

  • Heriot Row Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Heriot Row Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Heriot Row Response Time: Real-time P300 detection enables immediate assessment
  • Heriot Row Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Heriot Row Quality Assurance: Complete calibration validation ensures measurement integrity
This Heriot Row research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Heriot Row Lead Researcher

Heriot Row Practical Applications:

  • Heriot Row Forensic Psychology: Evidence-based assessment of concealed information
  • Heriot Row Security Screening: Reliable pre-employment and periodic assessments
  • Heriot Row Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Heriot Row Research Applications: Validated tool for memory and recognition studies
  • Heriot Row Clinical Assessment: Objective neurological evaluation with documented accuracy

From Heriot Row Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Heriot Row study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Heriot Row are grounded in published science rather than subjective opinion.

How the Heriot Row Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Heriot Row
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Heriot Row are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Heriot Row P300 Research?

This Heriot Row recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Heriot Row forensic and legal teams: seeking research-backed lie detector evidence
  • Heriot Row clinicians: requiring objective EEG markers for recognition and memory
  • Heriot Row security & compliance departments: interested in advanced screening tools
  • Heriot Row universities & labs: looking to build on validated P300 protocols

Heriot Row Future Research Directions

This foundational Heriot Row research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Heriot Row Planned Studies:

  • Heriot Row Multi-site Validation: Replication across multiple research centers
  • Heriot Row Population Diversity: Performance evaluation across demographic groups
  • Heriot Row Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Heriot Row Complex Scenarios: Real-world application validation studies
  • Heriot Row Machine Learning Integration: AI-enhanced pattern recognition development

Heriot Row P300 Research & Testing Services

Based on the success of this Heriot Row research study, we now offer comprehensive P300 recognition memory testing services throughout the Heriot Row area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Heriot Row Service Features:

  • Heriot Row Professional Testing: Certified EEG technicians serving Heriot Row research community
  • Heriot Row Complete Confidentiality: Strict privacy protection throughout Heriot Row area
  • Heriot Row Same-Day Results: Immediate analysis and reporting for Heriot Row clients
  • Heriot Row Academic Support: Research collaboration and data sharing for Heriot Row institutions
  • Heriot Row Mobile Testing: On-site testing at Heriot Row universities and research facilities
£2999
Heriot Row P300 Research Session
£4999
Heriot Row Full Study Package
£7999
Heriot Row Multi-Session Research
24/7
Heriot Row Research Support
"The Heriot Row P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Heriot Row Cognitive Research Director

Heriot Row Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Heriot Row?

P300 recognition memory research in Heriot Row involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Heriot Row study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Heriot Row research?

Our Heriot Row calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Heriot Row.

What are the key findings of the Heriot Row P300 recognition memory study?

Key findings from Heriot Row include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Heriot Row results show statistical significance and research reproducibility.

Is the Heriot Row research data available for academic use?

Yes, we provide access to anonymized Heriot Row research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Heriot Row P300 recognition memory research support?

Heriot Row applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Heriot Row?

Our Heriot Row validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.