Henlow Recognition Study September 15, 2024 n=75 Participants (Henlow) 8-week Henlow study

Henlow P300 Recognition Memory Research

Comprehensive controlled study conducted in Henlow documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Henlow participants.

Henlow Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Henlow

Ethics Approval: Henlow University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Henlow facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Henlow research

Study Period: September 15 - November 10, 2024 (8 weeks) in Henlow

Henlow Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Henlow participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Henlow participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Henlow participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Henlow guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Henlow testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Henlow with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Henlow Participants
95.2%
Henlow Accuracy
318ms
Henlow P300 Latency
11.3μV
Henlow Peak Amplitude

Henlow Plain-English Summary

In simple terms, this Henlow study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Henlow.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Henlow research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Henlow, particularly for cases where objective, research-backed evidence is important.

Henlow Pre-Test System Calibration

All Henlow testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Henlow participant testing commenced.

Henlow Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Henlow channels within ±0.2% tolerance

Henlow Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Henlow parameters within specification limits

Henlow Research Methodology

Week 1: Henlow Participant Recruitment & Randomization

75 healthy adults recruited through Henlow university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Henlow participants provided informed consent and completed health screening questionnaires.

Week 1-2: Henlow Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Henlow facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Henlow Controlled Testing Protocol

Henlow innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Henlow laboratory.

Week 6-7: Henlow Polygraph Comparison Testing

All Henlow participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Henlow Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Henlow study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Henlow P300 Recognition Response Analysis

Henlow Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Henlow Guilty P300 318ms, 11.3μV Henlow Innocent P300 315ms, 4.2μV Henlow Guilty Knowledge (n=35) Henlow Innocent Control (n=40)

Figure 1: Henlow grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Henlow groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Henlow 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Henlow guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Henlow Statistical Analysis & Performance Metrics

Henlow Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Henlow Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Henlow Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Henlow Difference - 7.1 - 6.0 - 8.2 3 ± 42

Henlow Statistical Significance Testing:

  • Henlow Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Henlow Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Henlow Effect Size: η² = 0.681 (large effect)
  • Henlow Power Analysis: β = 0.999 (excellent statistical power)
  • Henlow Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Henlow Detection Performance Metrics:

Henlow Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Henlow 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Henlow Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Henlow Improvement Ratio +81% +120% +98% +101% Immediate

Henlow Post-Test System Validation

Following completion of all Henlow participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Henlow Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Henlow Maximum drift: ±0.03% over 8-week period (Excellent stability)

Henlow Recognition Memory Research Key Findings

  • Henlow 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Henlow guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Henlow system calibration remained stable within ±0.03% over 8-week study period
  • Henlow response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Henlow EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Henlow participants
  • Henlow pre/post calibration validation confirms measurement reliability and traceability

Henlow Discussion & Clinical Implications

This controlled study conducted in Henlow demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Henlow Clinical Significance:

  • Henlow Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Henlow Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Henlow Response Time: Real-time P300 detection enables immediate assessment
  • Henlow Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Henlow Quality Assurance: Complete calibration validation ensures measurement integrity
This Henlow research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Henlow Lead Researcher

Henlow Practical Applications:

  • Henlow Forensic Psychology: Evidence-based assessment of concealed information
  • Henlow Security Screening: Reliable pre-employment and periodic assessments
  • Henlow Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Henlow Research Applications: Validated tool for memory and recognition studies
  • Henlow Clinical Assessment: Objective neurological evaluation with documented accuracy

From Henlow Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Henlow study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Henlow are grounded in published science rather than subjective opinion.

How the Henlow Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Henlow
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Henlow are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Henlow P300 Research?

This Henlow recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Henlow forensic and legal teams: seeking research-backed lie detector evidence
  • Henlow clinicians: requiring objective EEG markers for recognition and memory
  • Henlow security & compliance departments: interested in advanced screening tools
  • Henlow universities & labs: looking to build on validated P300 protocols

Henlow Future Research Directions

This foundational Henlow research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Henlow Planned Studies:

  • Henlow Multi-site Validation: Replication across multiple research centers
  • Henlow Population Diversity: Performance evaluation across demographic groups
  • Henlow Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Henlow Complex Scenarios: Real-world application validation studies
  • Henlow Machine Learning Integration: AI-enhanced pattern recognition development

Henlow P300 Research & Testing Services

Based on the success of this Henlow research study, we now offer comprehensive P300 recognition memory testing services throughout the Henlow area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Henlow Service Features:

  • Henlow Professional Testing: Certified EEG technicians serving Henlow research community
  • Henlow Complete Confidentiality: Strict privacy protection throughout Henlow area
  • Henlow Same-Day Results: Immediate analysis and reporting for Henlow clients
  • Henlow Academic Support: Research collaboration and data sharing for Henlow institutions
  • Henlow Mobile Testing: On-site testing at Henlow universities and research facilities
£2999
Henlow P300 Research Session
£4999
Henlow Full Study Package
£7999
Henlow Multi-Session Research
24/7
Henlow Research Support
"The Henlow P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Henlow Cognitive Research Director

Henlow Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Henlow?

P300 recognition memory research in Henlow involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Henlow study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Henlow research?

Our Henlow calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Henlow.

What are the key findings of the Henlow P300 recognition memory study?

Key findings from Henlow include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Henlow results show statistical significance and research reproducibility.

Is the Henlow research data available for academic use?

Yes, we provide access to anonymized Henlow research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Henlow P300 recognition memory research support?

Henlow applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Henlow?

Our Henlow validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.