Harlech Recognition Study September 15, 2024 n=75 Participants (Harlech) 8-week Harlech study

Harlech P300 Recognition Memory Research

Comprehensive controlled study conducted in Harlech documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Harlech participants.

Harlech Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Harlech

Ethics Approval: Harlech University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Harlech facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Harlech research

Study Period: September 15 - November 10, 2024 (8 weeks) in Harlech

Harlech Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Harlech participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Harlech participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Harlech participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Harlech guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Harlech testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Harlech with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Harlech Participants
95.2%
Harlech Accuracy
318ms
Harlech P300 Latency
11.3μV
Harlech Peak Amplitude

Harlech Plain-English Summary

In simple terms, this Harlech study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Harlech.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Harlech research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Harlech, particularly for cases where objective, research-backed evidence is important.

Harlech Pre-Test System Calibration

All Harlech testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Harlech participant testing commenced.

Harlech Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Harlech channels within ±0.2% tolerance

Harlech Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Harlech parameters within specification limits

Harlech Research Methodology

Week 1: Harlech Participant Recruitment & Randomization

75 healthy adults recruited through Harlech university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Harlech participants provided informed consent and completed health screening questionnaires.

Week 1-2: Harlech Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Harlech facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Harlech Controlled Testing Protocol

Harlech innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Harlech laboratory.

Week 6-7: Harlech Polygraph Comparison Testing

All Harlech participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Harlech Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Harlech study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Harlech P300 Recognition Response Analysis

Harlech Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Harlech Guilty P300 318ms, 11.3μV Harlech Innocent P300 315ms, 4.2μV Harlech Guilty Knowledge (n=35) Harlech Innocent Control (n=40)

Figure 1: Harlech grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Harlech groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Harlech 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Harlech guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Harlech Statistical Analysis & Performance Metrics

Harlech Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Harlech Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Harlech Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Harlech Difference - 7.1 - 6.0 - 8.2 3 ± 42

Harlech Statistical Significance Testing:

  • Harlech Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Harlech Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Harlech Effect Size: η² = 0.681 (large effect)
  • Harlech Power Analysis: β = 0.999 (excellent statistical power)
  • Harlech Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Harlech Detection Performance Metrics:

Harlech Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Harlech 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Harlech Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Harlech Improvement Ratio +81% +120% +98% +101% Immediate

Harlech Post-Test System Validation

Following completion of all Harlech participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Harlech Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Harlech Maximum drift: ±0.03% over 8-week period (Excellent stability)

Harlech Recognition Memory Research Key Findings

  • Harlech 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Harlech guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Harlech system calibration remained stable within ±0.03% over 8-week study period
  • Harlech response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Harlech EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Harlech participants
  • Harlech pre/post calibration validation confirms measurement reliability and traceability

Harlech Discussion & Clinical Implications

This controlled study conducted in Harlech demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Harlech Clinical Significance:

  • Harlech Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Harlech Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Harlech Response Time: Real-time P300 detection enables immediate assessment
  • Harlech Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Harlech Quality Assurance: Complete calibration validation ensures measurement integrity
This Harlech research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Harlech Lead Researcher

Harlech Practical Applications:

  • Harlech Forensic Psychology: Evidence-based assessment of concealed information
  • Harlech Security Screening: Reliable pre-employment and periodic assessments
  • Harlech Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Harlech Research Applications: Validated tool for memory and recognition studies
  • Harlech Clinical Assessment: Objective neurological evaluation with documented accuracy

From Harlech Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Harlech study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Harlech are grounded in published science rather than subjective opinion.

How the Harlech Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Harlech
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Harlech are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Harlech P300 Research?

This Harlech recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Harlech forensic and legal teams: seeking research-backed lie detector evidence
  • Harlech clinicians: requiring objective EEG markers for recognition and memory
  • Harlech security & compliance departments: interested in advanced screening tools
  • Harlech universities & labs: looking to build on validated P300 protocols

Harlech Future Research Directions

This foundational Harlech research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Harlech Planned Studies:

  • Harlech Multi-site Validation: Replication across multiple research centers
  • Harlech Population Diversity: Performance evaluation across demographic groups
  • Harlech Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Harlech Complex Scenarios: Real-world application validation studies
  • Harlech Machine Learning Integration: AI-enhanced pattern recognition development

Harlech P300 Research & Testing Services

Based on the success of this Harlech research study, we now offer comprehensive P300 recognition memory testing services throughout the Harlech area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Harlech Service Features:

  • Harlech Professional Testing: Certified EEG technicians serving Harlech research community
  • Harlech Complete Confidentiality: Strict privacy protection throughout Harlech area
  • Harlech Same-Day Results: Immediate analysis and reporting for Harlech clients
  • Harlech Academic Support: Research collaboration and data sharing for Harlech institutions
  • Harlech Mobile Testing: On-site testing at Harlech universities and research facilities
£2999
Harlech P300 Research Session
£4999
Harlech Full Study Package
£7999
Harlech Multi-Session Research
24/7
Harlech Research Support
"The Harlech P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Harlech Cognitive Research Director

Harlech Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Harlech?

P300 recognition memory research in Harlech involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Harlech study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Harlech research?

Our Harlech calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Harlech.

What are the key findings of the Harlech P300 recognition memory study?

Key findings from Harlech include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Harlech results show statistical significance and research reproducibility.

Is the Harlech research data available for academic use?

Yes, we provide access to anonymized Harlech research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Harlech P300 recognition memory research support?

Harlech applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Harlech?

Our Harlech validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.