Erith Recognition Study September 15, 2024 n=75 Participants (Erith) 8-week Erith study

Erith P300 Recognition Memory Research

Comprehensive controlled study conducted in Erith documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Erith participants.

Erith Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Erith

Ethics Approval: Erith University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Erith facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Erith research

Study Period: September 15 - November 10, 2024 (8 weeks) in Erith

Erith Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Erith participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Erith participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Erith participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Erith guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Erith testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Erith with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Erith Participants
95.2%
Erith Accuracy
318ms
Erith P300 Latency
11.3μV
Erith Peak Amplitude

Erith Plain-English Summary

In simple terms, this Erith study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Erith.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Erith research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Erith, particularly for cases where objective, research-backed evidence is important.

Erith Pre-Test System Calibration

All Erith testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Erith participant testing commenced.

Erith Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Erith channels within ±0.2% tolerance

Erith Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Erith parameters within specification limits

Erith Research Methodology

Week 1: Erith Participant Recruitment & Randomization

75 healthy adults recruited through Erith university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Erith participants provided informed consent and completed health screening questionnaires.

Week 1-2: Erith Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Erith facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Erith Controlled Testing Protocol

Erith innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Erith laboratory.

Week 6-7: Erith Polygraph Comparison Testing

All Erith participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Erith Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Erith study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Erith P300 Recognition Response Analysis

Erith Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Erith Guilty P300 318ms, 11.3μV Erith Innocent P300 315ms, 4.2μV Erith Guilty Knowledge (n=35) Erith Innocent Control (n=40)

Figure 1: Erith grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Erith groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Erith 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Erith guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Erith Statistical Analysis & Performance Metrics

Erith Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Erith Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Erith Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Erith Difference - 7.1 - 6.0 - 8.2 3 ± 42

Erith Statistical Significance Testing:

  • Erith Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Erith Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Erith Effect Size: η² = 0.681 (large effect)
  • Erith Power Analysis: β = 0.999 (excellent statistical power)
  • Erith Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Erith Detection Performance Metrics:

Erith Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Erith 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Erith Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Erith Improvement Ratio +81% +120% +98% +101% Immediate

Erith Post-Test System Validation

Following completion of all Erith participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Erith Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Erith Maximum drift: ±0.03% over 8-week period (Excellent stability)

Erith Recognition Memory Research Key Findings

  • Erith 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Erith guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Erith system calibration remained stable within ±0.03% over 8-week study period
  • Erith response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Erith EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Erith participants
  • Erith pre/post calibration validation confirms measurement reliability and traceability

Erith Discussion & Clinical Implications

This controlled study conducted in Erith demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Erith Clinical Significance:

  • Erith Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Erith Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Erith Response Time: Real-time P300 detection enables immediate assessment
  • Erith Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Erith Quality Assurance: Complete calibration validation ensures measurement integrity
This Erith research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Erith Lead Researcher

Erith Practical Applications:

  • Erith Forensic Psychology: Evidence-based assessment of concealed information
  • Erith Security Screening: Reliable pre-employment and periodic assessments
  • Erith Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Erith Research Applications: Validated tool for memory and recognition studies
  • Erith Clinical Assessment: Objective neurological evaluation with documented accuracy

From Erith Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Erith study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Erith are grounded in published science rather than subjective opinion.

How the Erith Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Erith
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Erith are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Erith P300 Research?

This Erith recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Erith forensic and legal teams: seeking research-backed lie detector evidence
  • Erith clinicians: requiring objective EEG markers for recognition and memory
  • Erith security & compliance departments: interested in advanced screening tools
  • Erith universities & labs: looking to build on validated P300 protocols

Erith Future Research Directions

This foundational Erith research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Erith Planned Studies:

  • Erith Multi-site Validation: Replication across multiple research centers
  • Erith Population Diversity: Performance evaluation across demographic groups
  • Erith Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Erith Complex Scenarios: Real-world application validation studies
  • Erith Machine Learning Integration: AI-enhanced pattern recognition development

Erith P300 Research & Testing Services

Based on the success of this Erith research study, we now offer comprehensive P300 recognition memory testing services throughout the Erith area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Erith Service Features:

  • Erith Professional Testing: Certified EEG technicians serving Erith research community
  • Erith Complete Confidentiality: Strict privacy protection throughout Erith area
  • Erith Same-Day Results: Immediate analysis and reporting for Erith clients
  • Erith Academic Support: Research collaboration and data sharing for Erith institutions
  • Erith Mobile Testing: On-site testing at Erith universities and research facilities
£2999
Erith P300 Research Session
£4999
Erith Full Study Package
£7999
Erith Multi-Session Research
24/7
Erith Research Support
"The Erith P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Erith Cognitive Research Director

Erith Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Erith?

P300 recognition memory research in Erith involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Erith study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Erith research?

Our Erith calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Erith.

What are the key findings of the Erith P300 recognition memory study?

Key findings from Erith include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Erith results show statistical significance and research reproducibility.

Is the Erith research data available for academic use?

Yes, we provide access to anonymized Erith research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Erith P300 recognition memory research support?

Erith applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Erith?

Our Erith validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.