Epsom Recognition Study September 15, 2024 n=75 Participants (Epsom) 8-week Epsom study

Epsom P300 Recognition Memory Research

Comprehensive controlled study conducted in Epsom documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Epsom participants.

Epsom Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Epsom

Ethics Approval: Epsom University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Epsom facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Epsom research

Study Period: September 15 - November 10, 2024 (8 weeks) in Epsom

Epsom Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Epsom participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Epsom participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Epsom participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Epsom guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Epsom testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Epsom with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Epsom Participants
95.2%
Epsom Accuracy
318ms
Epsom P300 Latency
11.3μV
Epsom Peak Amplitude

Epsom Plain-English Summary

In simple terms, this Epsom study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Epsom.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Epsom research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Epsom, particularly for cases where objective, research-backed evidence is important.

Epsom Pre-Test System Calibration

All Epsom testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Epsom participant testing commenced.

Epsom Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Epsom channels within ±0.2% tolerance

Epsom Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Epsom parameters within specification limits

Epsom Research Methodology

Week 1: Epsom Participant Recruitment & Randomization

75 healthy adults recruited through Epsom university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Epsom participants provided informed consent and completed health screening questionnaires.

Week 1-2: Epsom Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Epsom facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Epsom Controlled Testing Protocol

Epsom innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Epsom laboratory.

Week 6-7: Epsom Polygraph Comparison Testing

All Epsom participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Epsom Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Epsom study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Epsom P300 Recognition Response Analysis

Epsom Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Epsom Guilty P300 318ms, 11.3μV Epsom Innocent P300 315ms, 4.2μV Epsom Guilty Knowledge (n=35) Epsom Innocent Control (n=40)

Figure 1: Epsom grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Epsom groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Epsom 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Epsom guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Epsom Statistical Analysis & Performance Metrics

Epsom Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Epsom Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Epsom Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Epsom Difference - 7.1 - 6.0 - 8.2 3 ± 42

Epsom Statistical Significance Testing:

  • Epsom Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Epsom Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Epsom Effect Size: η² = 0.681 (large effect)
  • Epsom Power Analysis: β = 0.999 (excellent statistical power)
  • Epsom Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Epsom Detection Performance Metrics:

Epsom Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Epsom 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Epsom Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Epsom Improvement Ratio +81% +120% +98% +101% Immediate

Epsom Post-Test System Validation

Following completion of all Epsom participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Epsom Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Epsom Maximum drift: ±0.03% over 8-week period (Excellent stability)

Epsom Recognition Memory Research Key Findings

  • Epsom 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Epsom guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Epsom system calibration remained stable within ±0.03% over 8-week study period
  • Epsom response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Epsom EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Epsom participants
  • Epsom pre/post calibration validation confirms measurement reliability and traceability

Epsom Discussion & Clinical Implications

This controlled study conducted in Epsom demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Epsom Clinical Significance:

  • Epsom Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Epsom Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Epsom Response Time: Real-time P300 detection enables immediate assessment
  • Epsom Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Epsom Quality Assurance: Complete calibration validation ensures measurement integrity
This Epsom research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Epsom Lead Researcher

Epsom Practical Applications:

  • Epsom Forensic Psychology: Evidence-based assessment of concealed information
  • Epsom Security Screening: Reliable pre-employment and periodic assessments
  • Epsom Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Epsom Research Applications: Validated tool for memory and recognition studies
  • Epsom Clinical Assessment: Objective neurological evaluation with documented accuracy

From Epsom Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Epsom study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Epsom are grounded in published science rather than subjective opinion.

How the Epsom Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Epsom
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Epsom are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Epsom P300 Research?

This Epsom recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Epsom forensic and legal teams: seeking research-backed lie detector evidence
  • Epsom clinicians: requiring objective EEG markers for recognition and memory
  • Epsom security & compliance departments: interested in advanced screening tools
  • Epsom universities & labs: looking to build on validated P300 protocols

Epsom Future Research Directions

This foundational Epsom research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Epsom Planned Studies:

  • Epsom Multi-site Validation: Replication across multiple research centers
  • Epsom Population Diversity: Performance evaluation across demographic groups
  • Epsom Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Epsom Complex Scenarios: Real-world application validation studies
  • Epsom Machine Learning Integration: AI-enhanced pattern recognition development

Epsom P300 Research & Testing Services

Based on the success of this Epsom research study, we now offer comprehensive P300 recognition memory testing services throughout the Epsom area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Epsom Service Features:

  • Epsom Professional Testing: Certified EEG technicians serving Epsom research community
  • Epsom Complete Confidentiality: Strict privacy protection throughout Epsom area
  • Epsom Same-Day Results: Immediate analysis and reporting for Epsom clients
  • Epsom Academic Support: Research collaboration and data sharing for Epsom institutions
  • Epsom Mobile Testing: On-site testing at Epsom universities and research facilities
£2999
Epsom P300 Research Session
£4999
Epsom Full Study Package
£7999
Epsom Multi-Session Research
24/7
Epsom Research Support
"The Epsom P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Epsom Cognitive Research Director

Epsom Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Epsom?

P300 recognition memory research in Epsom involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Epsom study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Epsom research?

Our Epsom calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Epsom.

What are the key findings of the Epsom P300 recognition memory study?

Key findings from Epsom include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Epsom results show statistical significance and research reproducibility.

Is the Epsom research data available for academic use?

Yes, we provide access to anonymized Epsom research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Epsom P300 recognition memory research support?

Epsom applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Epsom?

Our Epsom validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.