Doonie Point Recognition Study September 15, 2024 n=75 Participants (Doonie Point) 8-week Doonie Point study

Doonie Point P300 Recognition Memory Research

Comprehensive controlled study conducted in Doonie Point documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Doonie Point participants.

Doonie Point Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Doonie Point

Ethics Approval: Doonie Point University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Doonie Point facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Doonie Point research

Study Period: September 15 - November 10, 2024 (8 weeks) in Doonie Point

Doonie Point Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Doonie Point participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Doonie Point participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Doonie Point participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Doonie Point guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Doonie Point testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Doonie Point with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Doonie Point Participants
95.2%
Doonie Point Accuracy
318ms
Doonie Point P300 Latency
11.3μV
Doonie Point Peak Amplitude

Doonie Point Plain-English Summary

In simple terms, this Doonie Point study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Doonie Point.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Doonie Point research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Doonie Point, particularly for cases where objective, research-backed evidence is important.

Doonie Point Pre-Test System Calibration

All Doonie Point testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Doonie Point participant testing commenced.

Doonie Point Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Doonie Point channels within ±0.2% tolerance

Doonie Point Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Doonie Point parameters within specification limits

Doonie Point Research Methodology

Week 1: Doonie Point Participant Recruitment & Randomization

75 healthy adults recruited through Doonie Point university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Doonie Point participants provided informed consent and completed health screening questionnaires.

Week 1-2: Doonie Point Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Doonie Point facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Doonie Point Controlled Testing Protocol

Doonie Point innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Doonie Point laboratory.

Week 6-7: Doonie Point Polygraph Comparison Testing

All Doonie Point participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Doonie Point Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Doonie Point study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Doonie Point P300 Recognition Response Analysis

Doonie Point Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Doonie Point Guilty P300 318ms, 11.3μV Doonie Point Innocent P300 315ms, 4.2μV Doonie Point Guilty Knowledge (n=35) Doonie Point Innocent Control (n=40)

Figure 1: Doonie Point grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Doonie Point groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Doonie Point 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Doonie Point guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Doonie Point Statistical Analysis & Performance Metrics

Doonie Point Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Doonie Point Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Doonie Point Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Doonie Point Difference - 7.1 - 6.0 - 8.2 3 ± 42

Doonie Point Statistical Significance Testing:

  • Doonie Point Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Doonie Point Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Doonie Point Effect Size: η² = 0.681 (large effect)
  • Doonie Point Power Analysis: β = 0.999 (excellent statistical power)
  • Doonie Point Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Doonie Point Detection Performance Metrics:

Doonie Point Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Doonie Point 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Doonie Point Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Doonie Point Improvement Ratio +81% +120% +98% +101% Immediate

Doonie Point Post-Test System Validation

Following completion of all Doonie Point participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Doonie Point Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Doonie Point Maximum drift: ±0.03% over 8-week period (Excellent stability)

Doonie Point Recognition Memory Research Key Findings

  • Doonie Point 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Doonie Point guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Doonie Point system calibration remained stable within ±0.03% over 8-week study period
  • Doonie Point response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Doonie Point EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Doonie Point participants
  • Doonie Point pre/post calibration validation confirms measurement reliability and traceability

Doonie Point Discussion & Clinical Implications

This controlled study conducted in Doonie Point demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Doonie Point Clinical Significance:

  • Doonie Point Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Doonie Point Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Doonie Point Response Time: Real-time P300 detection enables immediate assessment
  • Doonie Point Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Doonie Point Quality Assurance: Complete calibration validation ensures measurement integrity
This Doonie Point research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Doonie Point Lead Researcher

Doonie Point Practical Applications:

  • Doonie Point Forensic Psychology: Evidence-based assessment of concealed information
  • Doonie Point Security Screening: Reliable pre-employment and periodic assessments
  • Doonie Point Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Doonie Point Research Applications: Validated tool for memory and recognition studies
  • Doonie Point Clinical Assessment: Objective neurological evaluation with documented accuracy

From Doonie Point Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Doonie Point study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Doonie Point are grounded in published science rather than subjective opinion.

How the Doonie Point Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Doonie Point
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Doonie Point are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Doonie Point P300 Research?

This Doonie Point recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Doonie Point forensic and legal teams: seeking research-backed lie detector evidence
  • Doonie Point clinicians: requiring objective EEG markers for recognition and memory
  • Doonie Point security & compliance departments: interested in advanced screening tools
  • Doonie Point universities & labs: looking to build on validated P300 protocols

Doonie Point Future Research Directions

This foundational Doonie Point research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Doonie Point Planned Studies:

  • Doonie Point Multi-site Validation: Replication across multiple research centers
  • Doonie Point Population Diversity: Performance evaluation across demographic groups
  • Doonie Point Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Doonie Point Complex Scenarios: Real-world application validation studies
  • Doonie Point Machine Learning Integration: AI-enhanced pattern recognition development

Doonie Point P300 Research & Testing Services

Based on the success of this Doonie Point research study, we now offer comprehensive P300 recognition memory testing services throughout the Doonie Point area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Doonie Point Service Features:

  • Doonie Point Professional Testing: Certified EEG technicians serving Doonie Point research community
  • Doonie Point Complete Confidentiality: Strict privacy protection throughout Doonie Point area
  • Doonie Point Same-Day Results: Immediate analysis and reporting for Doonie Point clients
  • Doonie Point Academic Support: Research collaboration and data sharing for Doonie Point institutions
  • Doonie Point Mobile Testing: On-site testing at Doonie Point universities and research facilities
£2999
Doonie Point P300 Research Session
£4999
Doonie Point Full Study Package
£7999
Doonie Point Multi-Session Research
24/7
Doonie Point Research Support
"The Doonie Point P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Doonie Point Cognitive Research Director

Doonie Point Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Doonie Point?

P300 recognition memory research in Doonie Point involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Doonie Point study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Doonie Point research?

Our Doonie Point calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Doonie Point.

What are the key findings of the Doonie Point P300 recognition memory study?

Key findings from Doonie Point include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Doonie Point results show statistical significance and research reproducibility.

Is the Doonie Point research data available for academic use?

Yes, we provide access to anonymized Doonie Point research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Doonie Point P300 recognition memory research support?

Doonie Point applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Doonie Point?

Our Doonie Point validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.