Dimple Recognition Study September 15, 2024 n=75 Participants (Dimple) 8-week Dimple study

Dimple P300 Recognition Memory Research

Comprehensive controlled study conducted in Dimple documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Dimple participants.

Dimple Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Dimple

Ethics Approval: Dimple University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Dimple facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Dimple research

Study Period: September 15 - November 10, 2024 (8 weeks) in Dimple

Dimple Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Dimple participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Dimple participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Dimple participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Dimple guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Dimple testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Dimple with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Dimple Participants
95.2%
Dimple Accuracy
318ms
Dimple P300 Latency
11.3μV
Dimple Peak Amplitude

Dimple Plain-English Summary

In simple terms, this Dimple study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Dimple.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Dimple research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Dimple, particularly for cases where objective, research-backed evidence is important.

Dimple Pre-Test System Calibration

All Dimple testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Dimple participant testing commenced.

Dimple Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Dimple channels within ±0.2% tolerance

Dimple Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Dimple parameters within specification limits

Dimple Research Methodology

Week 1: Dimple Participant Recruitment & Randomization

75 healthy adults recruited through Dimple university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Dimple participants provided informed consent and completed health screening questionnaires.

Week 1-2: Dimple Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Dimple facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Dimple Controlled Testing Protocol

Dimple innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Dimple laboratory.

Week 6-7: Dimple Polygraph Comparison Testing

All Dimple participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Dimple Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Dimple study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Dimple P300 Recognition Response Analysis

Dimple Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Dimple Guilty P300 318ms, 11.3μV Dimple Innocent P300 315ms, 4.2μV Dimple Guilty Knowledge (n=35) Dimple Innocent Control (n=40)

Figure 1: Dimple grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Dimple groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Dimple 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Dimple guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Dimple Statistical Analysis & Performance Metrics

Dimple Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Dimple Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Dimple Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Dimple Difference - 7.1 - 6.0 - 8.2 3 ± 42

Dimple Statistical Significance Testing:

  • Dimple Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Dimple Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Dimple Effect Size: η² = 0.681 (large effect)
  • Dimple Power Analysis: β = 0.999 (excellent statistical power)
  • Dimple Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Dimple Detection Performance Metrics:

Dimple Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Dimple 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Dimple Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Dimple Improvement Ratio +81% +120% +98% +101% Immediate

Dimple Post-Test System Validation

Following completion of all Dimple participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Dimple Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Dimple Maximum drift: ±0.03% over 8-week period (Excellent stability)

Dimple Recognition Memory Research Key Findings

  • Dimple 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Dimple guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Dimple system calibration remained stable within ±0.03% over 8-week study period
  • Dimple response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Dimple EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Dimple participants
  • Dimple pre/post calibration validation confirms measurement reliability and traceability

Dimple Discussion & Clinical Implications

This controlled study conducted in Dimple demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Dimple Clinical Significance:

  • Dimple Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Dimple Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Dimple Response Time: Real-time P300 detection enables immediate assessment
  • Dimple Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Dimple Quality Assurance: Complete calibration validation ensures measurement integrity
This Dimple research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Dimple Lead Researcher

Dimple Practical Applications:

  • Dimple Forensic Psychology: Evidence-based assessment of concealed information
  • Dimple Security Screening: Reliable pre-employment and periodic assessments
  • Dimple Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Dimple Research Applications: Validated tool for memory and recognition studies
  • Dimple Clinical Assessment: Objective neurological evaluation with documented accuracy

From Dimple Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Dimple study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Dimple are grounded in published science rather than subjective opinion.

How the Dimple Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Dimple
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Dimple are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Dimple P300 Research?

This Dimple recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Dimple forensic and legal teams: seeking research-backed lie detector evidence
  • Dimple clinicians: requiring objective EEG markers for recognition and memory
  • Dimple security & compliance departments: interested in advanced screening tools
  • Dimple universities & labs: looking to build on validated P300 protocols

Dimple Future Research Directions

This foundational Dimple research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Dimple Planned Studies:

  • Dimple Multi-site Validation: Replication across multiple research centers
  • Dimple Population Diversity: Performance evaluation across demographic groups
  • Dimple Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Dimple Complex Scenarios: Real-world application validation studies
  • Dimple Machine Learning Integration: AI-enhanced pattern recognition development

Dimple P300 Research & Testing Services

Based on the success of this Dimple research study, we now offer comprehensive P300 recognition memory testing services throughout the Dimple area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Dimple Service Features:

  • Dimple Professional Testing: Certified EEG technicians serving Dimple research community
  • Dimple Complete Confidentiality: Strict privacy protection throughout Dimple area
  • Dimple Same-Day Results: Immediate analysis and reporting for Dimple clients
  • Dimple Academic Support: Research collaboration and data sharing for Dimple institutions
  • Dimple Mobile Testing: On-site testing at Dimple universities and research facilities
£2999
Dimple P300 Research Session
£4999
Dimple Full Study Package
£7999
Dimple Multi-Session Research
24/7
Dimple Research Support
"The Dimple P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Dimple Cognitive Research Director

Dimple Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Dimple?

P300 recognition memory research in Dimple involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Dimple study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Dimple research?

Our Dimple calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Dimple.

What are the key findings of the Dimple P300 recognition memory study?

Key findings from Dimple include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Dimple results show statistical significance and research reproducibility.

Is the Dimple research data available for academic use?

Yes, we provide access to anonymized Dimple research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Dimple P300 recognition memory research support?

Dimple applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Dimple?

Our Dimple validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.