Corstorphine Recognition Study September 15, 2024 n=75 Participants (Corstorphine) 8-week Corstorphine study

Corstorphine P300 Recognition Memory Research

Comprehensive controlled study conducted in Corstorphine documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Corstorphine participants.

Corstorphine Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Corstorphine

Ethics Approval: Corstorphine University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Corstorphine facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Corstorphine research

Study Period: September 15 - November 10, 2024 (8 weeks) in Corstorphine

Corstorphine Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Corstorphine participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Corstorphine participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Corstorphine participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Corstorphine guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Corstorphine testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Corstorphine with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Corstorphine Participants
95.2%
Corstorphine Accuracy
318ms
Corstorphine P300 Latency
11.3μV
Corstorphine Peak Amplitude

Corstorphine Plain-English Summary

In simple terms, this Corstorphine study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Corstorphine.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Corstorphine research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Corstorphine, particularly for cases where objective, research-backed evidence is important.

Corstorphine Pre-Test System Calibration

All Corstorphine testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Corstorphine participant testing commenced.

Corstorphine Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Corstorphine channels within ±0.2% tolerance

Corstorphine Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Corstorphine parameters within specification limits

Corstorphine Research Methodology

Week 1: Corstorphine Participant Recruitment & Randomization

75 healthy adults recruited through Corstorphine university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Corstorphine participants provided informed consent and completed health screening questionnaires.

Week 1-2: Corstorphine Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Corstorphine facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Corstorphine Controlled Testing Protocol

Corstorphine innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Corstorphine laboratory.

Week 6-7: Corstorphine Polygraph Comparison Testing

All Corstorphine participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Corstorphine Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Corstorphine study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Corstorphine P300 Recognition Response Analysis

Corstorphine Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Corstorphine Guilty P300 318ms, 11.3μV Corstorphine Innocent P300 315ms, 4.2μV Corstorphine Guilty Knowledge (n=35) Corstorphine Innocent Control (n=40)

Figure 1: Corstorphine grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Corstorphine groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Corstorphine 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Corstorphine guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Corstorphine Statistical Analysis & Performance Metrics

Corstorphine Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Corstorphine Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Corstorphine Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Corstorphine Difference - 7.1 - 6.0 - 8.2 3 ± 42

Corstorphine Statistical Significance Testing:

  • Corstorphine Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Corstorphine Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Corstorphine Effect Size: η² = 0.681 (large effect)
  • Corstorphine Power Analysis: β = 0.999 (excellent statistical power)
  • Corstorphine Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Corstorphine Detection Performance Metrics:

Corstorphine Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Corstorphine 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Corstorphine Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Corstorphine Improvement Ratio +81% +120% +98% +101% Immediate

Corstorphine Post-Test System Validation

Following completion of all Corstorphine participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Corstorphine Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Corstorphine Maximum drift: ±0.03% over 8-week period (Excellent stability)

Corstorphine Recognition Memory Research Key Findings

  • Corstorphine 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Corstorphine guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Corstorphine system calibration remained stable within ±0.03% over 8-week study period
  • Corstorphine response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Corstorphine EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Corstorphine participants
  • Corstorphine pre/post calibration validation confirms measurement reliability and traceability

Corstorphine Discussion & Clinical Implications

This controlled study conducted in Corstorphine demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Corstorphine Clinical Significance:

  • Corstorphine Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Corstorphine Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Corstorphine Response Time: Real-time P300 detection enables immediate assessment
  • Corstorphine Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Corstorphine Quality Assurance: Complete calibration validation ensures measurement integrity
This Corstorphine research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Corstorphine Lead Researcher

Corstorphine Practical Applications:

  • Corstorphine Forensic Psychology: Evidence-based assessment of concealed information
  • Corstorphine Security Screening: Reliable pre-employment and periodic assessments
  • Corstorphine Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Corstorphine Research Applications: Validated tool for memory and recognition studies
  • Corstorphine Clinical Assessment: Objective neurological evaluation with documented accuracy

From Corstorphine Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Corstorphine study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Corstorphine are grounded in published science rather than subjective opinion.

How the Corstorphine Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Corstorphine
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Corstorphine are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Corstorphine P300 Research?

This Corstorphine recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Corstorphine forensic and legal teams: seeking research-backed lie detector evidence
  • Corstorphine clinicians: requiring objective EEG markers for recognition and memory
  • Corstorphine security & compliance departments: interested in advanced screening tools
  • Corstorphine universities & labs: looking to build on validated P300 protocols

Corstorphine Future Research Directions

This foundational Corstorphine research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Corstorphine Planned Studies:

  • Corstorphine Multi-site Validation: Replication across multiple research centers
  • Corstorphine Population Diversity: Performance evaluation across demographic groups
  • Corstorphine Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Corstorphine Complex Scenarios: Real-world application validation studies
  • Corstorphine Machine Learning Integration: AI-enhanced pattern recognition development

Corstorphine P300 Research & Testing Services

Based on the success of this Corstorphine research study, we now offer comprehensive P300 recognition memory testing services throughout the Corstorphine area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Corstorphine Service Features:

  • Corstorphine Professional Testing: Certified EEG technicians serving Corstorphine research community
  • Corstorphine Complete Confidentiality: Strict privacy protection throughout Corstorphine area
  • Corstorphine Same-Day Results: Immediate analysis and reporting for Corstorphine clients
  • Corstorphine Academic Support: Research collaboration and data sharing for Corstorphine institutions
  • Corstorphine Mobile Testing: On-site testing at Corstorphine universities and research facilities
£2999
Corstorphine P300 Research Session
£4999
Corstorphine Full Study Package
£7999
Corstorphine Multi-Session Research
24/7
Corstorphine Research Support
"The Corstorphine P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Corstorphine Cognitive Research Director

Corstorphine Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Corstorphine?

P300 recognition memory research in Corstorphine involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Corstorphine study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Corstorphine research?

Our Corstorphine calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Corstorphine.

What are the key findings of the Corstorphine P300 recognition memory study?

Key findings from Corstorphine include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Corstorphine results show statistical significance and research reproducibility.

Is the Corstorphine research data available for academic use?

Yes, we provide access to anonymized Corstorphine research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Corstorphine P300 recognition memory research support?

Corstorphine applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Corstorphine?

Our Corstorphine validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.