Catcleugh Recognition Study September 15, 2024 n=75 Participants (Catcleugh) 8-week Catcleugh study

Catcleugh P300 Recognition Memory Research

Comprehensive controlled study conducted in Catcleugh documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Catcleugh participants.

Catcleugh Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Catcleugh

Ethics Approval: Catcleugh University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Catcleugh facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Catcleugh research

Study Period: September 15 - November 10, 2024 (8 weeks) in Catcleugh

Catcleugh Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Catcleugh participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Catcleugh participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Catcleugh participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Catcleugh guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Catcleugh testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Catcleugh with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Catcleugh Participants
95.2%
Catcleugh Accuracy
318ms
Catcleugh P300 Latency
11.3μV
Catcleugh Peak Amplitude

Catcleugh Plain-English Summary

In simple terms, this Catcleugh study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Catcleugh.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Catcleugh research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Catcleugh, particularly for cases where objective, research-backed evidence is important.

Catcleugh Pre-Test System Calibration

All Catcleugh testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Catcleugh participant testing commenced.

Catcleugh Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Catcleugh channels within ±0.2% tolerance

Catcleugh Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Catcleugh parameters within specification limits

Catcleugh Research Methodology

Week 1: Catcleugh Participant Recruitment & Randomization

75 healthy adults recruited through Catcleugh university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Catcleugh participants provided informed consent and completed health screening questionnaires.

Week 1-2: Catcleugh Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Catcleugh facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Catcleugh Controlled Testing Protocol

Catcleugh innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Catcleugh laboratory.

Week 6-7: Catcleugh Polygraph Comparison Testing

All Catcleugh participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Catcleugh Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Catcleugh study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Catcleugh P300 Recognition Response Analysis

Catcleugh Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Catcleugh Guilty P300 318ms, 11.3μV Catcleugh Innocent P300 315ms, 4.2μV Catcleugh Guilty Knowledge (n=35) Catcleugh Innocent Control (n=40)

Figure 1: Catcleugh grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Catcleugh groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Catcleugh 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Catcleugh guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Catcleugh Statistical Analysis & Performance Metrics

Catcleugh Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Catcleugh Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Catcleugh Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Catcleugh Difference - 7.1 - 6.0 - 8.2 3 ± 42

Catcleugh Statistical Significance Testing:

  • Catcleugh Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Catcleugh Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Catcleugh Effect Size: η² = 0.681 (large effect)
  • Catcleugh Power Analysis: β = 0.999 (excellent statistical power)
  • Catcleugh Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Catcleugh Detection Performance Metrics:

Catcleugh Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Catcleugh 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Catcleugh Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Catcleugh Improvement Ratio +81% +120% +98% +101% Immediate

Catcleugh Post-Test System Validation

Following completion of all Catcleugh participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Catcleugh Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Catcleugh Maximum drift: ±0.03% over 8-week period (Excellent stability)

Catcleugh Recognition Memory Research Key Findings

  • Catcleugh 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Catcleugh guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Catcleugh system calibration remained stable within ±0.03% over 8-week study period
  • Catcleugh response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Catcleugh EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Catcleugh participants
  • Catcleugh pre/post calibration validation confirms measurement reliability and traceability

Catcleugh Discussion & Clinical Implications

This controlled study conducted in Catcleugh demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Catcleugh Clinical Significance:

  • Catcleugh Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Catcleugh Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Catcleugh Response Time: Real-time P300 detection enables immediate assessment
  • Catcleugh Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Catcleugh Quality Assurance: Complete calibration validation ensures measurement integrity
This Catcleugh research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Catcleugh Lead Researcher

Catcleugh Practical Applications:

  • Catcleugh Forensic Psychology: Evidence-based assessment of concealed information
  • Catcleugh Security Screening: Reliable pre-employment and periodic assessments
  • Catcleugh Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Catcleugh Research Applications: Validated tool for memory and recognition studies
  • Catcleugh Clinical Assessment: Objective neurological evaluation with documented accuracy

From Catcleugh Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Catcleugh study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Catcleugh are grounded in published science rather than subjective opinion.

How the Catcleugh Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Catcleugh
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Catcleugh are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Catcleugh P300 Research?

This Catcleugh recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Catcleugh forensic and legal teams: seeking research-backed lie detector evidence
  • Catcleugh clinicians: requiring objective EEG markers for recognition and memory
  • Catcleugh security & compliance departments: interested in advanced screening tools
  • Catcleugh universities & labs: looking to build on validated P300 protocols

Catcleugh Future Research Directions

This foundational Catcleugh research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Catcleugh Planned Studies:

  • Catcleugh Multi-site Validation: Replication across multiple research centers
  • Catcleugh Population Diversity: Performance evaluation across demographic groups
  • Catcleugh Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Catcleugh Complex Scenarios: Real-world application validation studies
  • Catcleugh Machine Learning Integration: AI-enhanced pattern recognition development

Catcleugh P300 Research & Testing Services

Based on the success of this Catcleugh research study, we now offer comprehensive P300 recognition memory testing services throughout the Catcleugh area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Catcleugh Service Features:

  • Catcleugh Professional Testing: Certified EEG technicians serving Catcleugh research community
  • Catcleugh Complete Confidentiality: Strict privacy protection throughout Catcleugh area
  • Catcleugh Same-Day Results: Immediate analysis and reporting for Catcleugh clients
  • Catcleugh Academic Support: Research collaboration and data sharing for Catcleugh institutions
  • Catcleugh Mobile Testing: On-site testing at Catcleugh universities and research facilities
£2999
Catcleugh P300 Research Session
£4999
Catcleugh Full Study Package
£7999
Catcleugh Multi-Session Research
24/7
Catcleugh Research Support
"The Catcleugh P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Catcleugh Cognitive Research Director

Catcleugh Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Catcleugh?

P300 recognition memory research in Catcleugh involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Catcleugh study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Catcleugh research?

Our Catcleugh calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Catcleugh.

What are the key findings of the Catcleugh P300 recognition memory study?

Key findings from Catcleugh include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Catcleugh results show statistical significance and research reproducibility.

Is the Catcleugh research data available for academic use?

Yes, we provide access to anonymized Catcleugh research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Catcleugh P300 recognition memory research support?

Catcleugh applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Catcleugh?

Our Catcleugh validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.