Caledon Recognition Study September 15, 2024 n=75 Participants (Caledon) 8-week Caledon study

Caledon P300 Recognition Memory Research

Comprehensive controlled study conducted in Caledon documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Caledon participants.

Caledon Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Caledon

Ethics Approval: Caledon University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Caledon facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Caledon research

Study Period: September 15 - November 10, 2024 (8 weeks) in Caledon

Caledon Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Caledon participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Caledon participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Caledon participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Caledon guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Caledon testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Caledon with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Caledon Participants
95.2%
Caledon Accuracy
318ms
Caledon P300 Latency
11.3μV
Caledon Peak Amplitude

Caledon Plain-English Summary

In simple terms, this Caledon study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Caledon.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Caledon research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Caledon, particularly for cases where objective, research-backed evidence is important.

Caledon Pre-Test System Calibration

All Caledon testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Caledon participant testing commenced.

Caledon Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Caledon channels within ±0.2% tolerance

Caledon Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Caledon parameters within specification limits

Caledon Research Methodology

Week 1: Caledon Participant Recruitment & Randomization

75 healthy adults recruited through Caledon university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Caledon participants provided informed consent and completed health screening questionnaires.

Week 1-2: Caledon Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Caledon facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Caledon Controlled Testing Protocol

Caledon innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Caledon laboratory.

Week 6-7: Caledon Polygraph Comparison Testing

All Caledon participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Caledon Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Caledon study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Caledon P300 Recognition Response Analysis

Caledon Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Caledon Guilty P300 318ms, 11.3μV Caledon Innocent P300 315ms, 4.2μV Caledon Guilty Knowledge (n=35) Caledon Innocent Control (n=40)

Figure 1: Caledon grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Caledon groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Caledon 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Caledon guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Caledon Statistical Analysis & Performance Metrics

Caledon Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Caledon Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Caledon Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Caledon Difference - 7.1 - 6.0 - 8.2 3 ± 42

Caledon Statistical Significance Testing:

  • Caledon Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Caledon Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Caledon Effect Size: η² = 0.681 (large effect)
  • Caledon Power Analysis: β = 0.999 (excellent statistical power)
  • Caledon Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Caledon Detection Performance Metrics:

Caledon Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Caledon 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Caledon Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Caledon Improvement Ratio +81% +120% +98% +101% Immediate

Caledon Post-Test System Validation

Following completion of all Caledon participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Caledon Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Caledon Maximum drift: ±0.03% over 8-week period (Excellent stability)

Caledon Recognition Memory Research Key Findings

  • Caledon 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Caledon guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Caledon system calibration remained stable within ±0.03% over 8-week study period
  • Caledon response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Caledon EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Caledon participants
  • Caledon pre/post calibration validation confirms measurement reliability and traceability

Caledon Discussion & Clinical Implications

This controlled study conducted in Caledon demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Caledon Clinical Significance:

  • Caledon Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Caledon Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Caledon Response Time: Real-time P300 detection enables immediate assessment
  • Caledon Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Caledon Quality Assurance: Complete calibration validation ensures measurement integrity
This Caledon research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Caledon Lead Researcher

Caledon Practical Applications:

  • Caledon Forensic Psychology: Evidence-based assessment of concealed information
  • Caledon Security Screening: Reliable pre-employment and periodic assessments
  • Caledon Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Caledon Research Applications: Validated tool for memory and recognition studies
  • Caledon Clinical Assessment: Objective neurological evaluation with documented accuracy

From Caledon Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Caledon study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Caledon are grounded in published science rather than subjective opinion.

How the Caledon Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Caledon
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Caledon are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Caledon P300 Research?

This Caledon recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Caledon forensic and legal teams: seeking research-backed lie detector evidence
  • Caledon clinicians: requiring objective EEG markers for recognition and memory
  • Caledon security & compliance departments: interested in advanced screening tools
  • Caledon universities & labs: looking to build on validated P300 protocols

Caledon Future Research Directions

This foundational Caledon research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Caledon Planned Studies:

  • Caledon Multi-site Validation: Replication across multiple research centers
  • Caledon Population Diversity: Performance evaluation across demographic groups
  • Caledon Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Caledon Complex Scenarios: Real-world application validation studies
  • Caledon Machine Learning Integration: AI-enhanced pattern recognition development

Caledon P300 Research & Testing Services

Based on the success of this Caledon research study, we now offer comprehensive P300 recognition memory testing services throughout the Caledon area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Caledon Service Features:

  • Caledon Professional Testing: Certified EEG technicians serving Caledon research community
  • Caledon Complete Confidentiality: Strict privacy protection throughout Caledon area
  • Caledon Same-Day Results: Immediate analysis and reporting for Caledon clients
  • Caledon Academic Support: Research collaboration and data sharing for Caledon institutions
  • Caledon Mobile Testing: On-site testing at Caledon universities and research facilities
£2999
Caledon P300 Research Session
£4999
Caledon Full Study Package
£7999
Caledon Multi-Session Research
24/7
Caledon Research Support
"The Caledon P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Caledon Cognitive Research Director

Caledon Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Caledon?

P300 recognition memory research in Caledon involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Caledon study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Caledon research?

Our Caledon calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Caledon.

What are the key findings of the Caledon P300 recognition memory study?

Key findings from Caledon include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Caledon results show statistical significance and research reproducibility.

Is the Caledon research data available for academic use?

Yes, we provide access to anonymized Caledon research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Caledon P300 recognition memory research support?

Caledon applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Caledon?

Our Caledon validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.