Burnhaven Recognition Study September 15, 2024 n=75 Participants (Burnhaven) 8-week Burnhaven study

Burnhaven P300 Recognition Memory Research

Comprehensive controlled study conducted in Burnhaven documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Burnhaven participants.

Burnhaven Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Burnhaven

Ethics Approval: Burnhaven University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Burnhaven facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Burnhaven research

Study Period: September 15 - November 10, 2024 (8 weeks) in Burnhaven

Burnhaven Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Burnhaven participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Burnhaven participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Burnhaven participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Burnhaven guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Burnhaven testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Burnhaven with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Burnhaven Participants
95.2%
Burnhaven Accuracy
318ms
Burnhaven P300 Latency
11.3μV
Burnhaven Peak Amplitude

Burnhaven Plain-English Summary

In simple terms, this Burnhaven study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Burnhaven.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Burnhaven research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Burnhaven, particularly for cases where objective, research-backed evidence is important.

Burnhaven Pre-Test System Calibration

All Burnhaven testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Burnhaven participant testing commenced.

Burnhaven Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Burnhaven channels within ±0.2% tolerance

Burnhaven Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Burnhaven parameters within specification limits

Burnhaven Research Methodology

Week 1: Burnhaven Participant Recruitment & Randomization

75 healthy adults recruited through Burnhaven university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Burnhaven participants provided informed consent and completed health screening questionnaires.

Week 1-2: Burnhaven Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Burnhaven facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Burnhaven Controlled Testing Protocol

Burnhaven innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Burnhaven laboratory.

Week 6-7: Burnhaven Polygraph Comparison Testing

All Burnhaven participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Burnhaven Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Burnhaven study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Burnhaven P300 Recognition Response Analysis

Burnhaven Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Burnhaven Guilty P300 318ms, 11.3μV Burnhaven Innocent P300 315ms, 4.2μV Burnhaven Guilty Knowledge (n=35) Burnhaven Innocent Control (n=40)

Figure 1: Burnhaven grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Burnhaven groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Burnhaven 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Burnhaven guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Burnhaven Statistical Analysis & Performance Metrics

Burnhaven Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Burnhaven Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Burnhaven Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Burnhaven Difference - 7.1 - 6.0 - 8.2 3 ± 42

Burnhaven Statistical Significance Testing:

  • Burnhaven Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Burnhaven Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Burnhaven Effect Size: η² = 0.681 (large effect)
  • Burnhaven Power Analysis: β = 0.999 (excellent statistical power)
  • Burnhaven Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Burnhaven Detection Performance Metrics:

Burnhaven Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Burnhaven 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Burnhaven Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Burnhaven Improvement Ratio +81% +120% +98% +101% Immediate

Burnhaven Post-Test System Validation

Following completion of all Burnhaven participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Burnhaven Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Burnhaven Maximum drift: ±0.03% over 8-week period (Excellent stability)

Burnhaven Recognition Memory Research Key Findings

  • Burnhaven 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Burnhaven guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Burnhaven system calibration remained stable within ±0.03% over 8-week study period
  • Burnhaven response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Burnhaven EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Burnhaven participants
  • Burnhaven pre/post calibration validation confirms measurement reliability and traceability

Burnhaven Discussion & Clinical Implications

This controlled study conducted in Burnhaven demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Burnhaven Clinical Significance:

  • Burnhaven Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Burnhaven Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Burnhaven Response Time: Real-time P300 detection enables immediate assessment
  • Burnhaven Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Burnhaven Quality Assurance: Complete calibration validation ensures measurement integrity
This Burnhaven research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Burnhaven Lead Researcher

Burnhaven Practical Applications:

  • Burnhaven Forensic Psychology: Evidence-based assessment of concealed information
  • Burnhaven Security Screening: Reliable pre-employment and periodic assessments
  • Burnhaven Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Burnhaven Research Applications: Validated tool for memory and recognition studies
  • Burnhaven Clinical Assessment: Objective neurological evaluation with documented accuracy

From Burnhaven Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Burnhaven study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Burnhaven are grounded in published science rather than subjective opinion.

How the Burnhaven Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Burnhaven
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Burnhaven are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Burnhaven P300 Research?

This Burnhaven recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Burnhaven forensic and legal teams: seeking research-backed lie detector evidence
  • Burnhaven clinicians: requiring objective EEG markers for recognition and memory
  • Burnhaven security & compliance departments: interested in advanced screening tools
  • Burnhaven universities & labs: looking to build on validated P300 protocols

Burnhaven Future Research Directions

This foundational Burnhaven research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Burnhaven Planned Studies:

  • Burnhaven Multi-site Validation: Replication across multiple research centers
  • Burnhaven Population Diversity: Performance evaluation across demographic groups
  • Burnhaven Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Burnhaven Complex Scenarios: Real-world application validation studies
  • Burnhaven Machine Learning Integration: AI-enhanced pattern recognition development

Burnhaven P300 Research & Testing Services

Based on the success of this Burnhaven research study, we now offer comprehensive P300 recognition memory testing services throughout the Burnhaven area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Burnhaven Service Features:

  • Burnhaven Professional Testing: Certified EEG technicians serving Burnhaven research community
  • Burnhaven Complete Confidentiality: Strict privacy protection throughout Burnhaven area
  • Burnhaven Same-Day Results: Immediate analysis and reporting for Burnhaven clients
  • Burnhaven Academic Support: Research collaboration and data sharing for Burnhaven institutions
  • Burnhaven Mobile Testing: On-site testing at Burnhaven universities and research facilities
£2999
Burnhaven P300 Research Session
£4999
Burnhaven Full Study Package
£7999
Burnhaven Multi-Session Research
24/7
Burnhaven Research Support
"The Burnhaven P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Burnhaven Cognitive Research Director

Burnhaven Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Burnhaven?

P300 recognition memory research in Burnhaven involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Burnhaven study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Burnhaven research?

Our Burnhaven calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Burnhaven.

What are the key findings of the Burnhaven P300 recognition memory study?

Key findings from Burnhaven include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Burnhaven results show statistical significance and research reproducibility.

Is the Burnhaven research data available for academic use?

Yes, we provide access to anonymized Burnhaven research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Burnhaven P300 recognition memory research support?

Burnhaven applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Burnhaven?

Our Burnhaven validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.