Burford Recognition Study September 15, 2024 n=75 Participants (Burford) 8-week Burford study

Burford P300 Recognition Memory Research

Comprehensive controlled study conducted in Burford documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Burford participants.

Burford Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Burford

Ethics Approval: Burford University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Burford facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Burford research

Study Period: September 15 - November 10, 2024 (8 weeks) in Burford

Burford Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Burford participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Burford participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Burford participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Burford guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Burford testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Burford with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Burford Participants
95.2%
Burford Accuracy
318ms
Burford P300 Latency
11.3μV
Burford Peak Amplitude

Burford Plain-English Summary

In simple terms, this Burford study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Burford.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Burford research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Burford, particularly for cases where objective, research-backed evidence is important.

Burford Pre-Test System Calibration

All Burford testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Burford participant testing commenced.

Burford Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Burford channels within ±0.2% tolerance

Burford Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Burford parameters within specification limits

Burford Research Methodology

Week 1: Burford Participant Recruitment & Randomization

75 healthy adults recruited through Burford university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Burford participants provided informed consent and completed health screening questionnaires.

Week 1-2: Burford Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Burford facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Burford Controlled Testing Protocol

Burford innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Burford laboratory.

Week 6-7: Burford Polygraph Comparison Testing

All Burford participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Burford Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Burford study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Burford P300 Recognition Response Analysis

Burford Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Burford Guilty P300 318ms, 11.3μV Burford Innocent P300 315ms, 4.2μV Burford Guilty Knowledge (n=35) Burford Innocent Control (n=40)

Figure 1: Burford grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Burford groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Burford 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Burford guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Burford Statistical Analysis & Performance Metrics

Burford Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Burford Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Burford Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Burford Difference - 7.1 - 6.0 - 8.2 3 ± 42

Burford Statistical Significance Testing:

  • Burford Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Burford Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Burford Effect Size: η² = 0.681 (large effect)
  • Burford Power Analysis: β = 0.999 (excellent statistical power)
  • Burford Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Burford Detection Performance Metrics:

Burford Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Burford 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Burford Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Burford Improvement Ratio +81% +120% +98% +101% Immediate

Burford Post-Test System Validation

Following completion of all Burford participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Burford Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Burford Maximum drift: ±0.03% over 8-week period (Excellent stability)

Burford Recognition Memory Research Key Findings

  • Burford 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Burford guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Burford system calibration remained stable within ±0.03% over 8-week study period
  • Burford response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Burford EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Burford participants
  • Burford pre/post calibration validation confirms measurement reliability and traceability

Burford Discussion & Clinical Implications

This controlled study conducted in Burford demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Burford Clinical Significance:

  • Burford Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Burford Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Burford Response Time: Real-time P300 detection enables immediate assessment
  • Burford Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Burford Quality Assurance: Complete calibration validation ensures measurement integrity
This Burford research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Burford Lead Researcher

Burford Practical Applications:

  • Burford Forensic Psychology: Evidence-based assessment of concealed information
  • Burford Security Screening: Reliable pre-employment and periodic assessments
  • Burford Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Burford Research Applications: Validated tool for memory and recognition studies
  • Burford Clinical Assessment: Objective neurological evaluation with documented accuracy

From Burford Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Burford study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Burford are grounded in published science rather than subjective opinion.

How the Burford Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Burford
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Burford are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Burford P300 Research?

This Burford recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Burford forensic and legal teams: seeking research-backed lie detector evidence
  • Burford clinicians: requiring objective EEG markers for recognition and memory
  • Burford security & compliance departments: interested in advanced screening tools
  • Burford universities & labs: looking to build on validated P300 protocols

Burford Future Research Directions

This foundational Burford research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Burford Planned Studies:

  • Burford Multi-site Validation: Replication across multiple research centers
  • Burford Population Diversity: Performance evaluation across demographic groups
  • Burford Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Burford Complex Scenarios: Real-world application validation studies
  • Burford Machine Learning Integration: AI-enhanced pattern recognition development

Burford P300 Research & Testing Services

Based on the success of this Burford research study, we now offer comprehensive P300 recognition memory testing services throughout the Burford area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Burford Service Features:

  • Burford Professional Testing: Certified EEG technicians serving Burford research community
  • Burford Complete Confidentiality: Strict privacy protection throughout Burford area
  • Burford Same-Day Results: Immediate analysis and reporting for Burford clients
  • Burford Academic Support: Research collaboration and data sharing for Burford institutions
  • Burford Mobile Testing: On-site testing at Burford universities and research facilities
£2999
Burford P300 Research Session
£4999
Burford Full Study Package
£7999
Burford Multi-Session Research
24/7
Burford Research Support
"The Burford P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Burford Cognitive Research Director

Burford Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Burford?

P300 recognition memory research in Burford involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Burford study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Burford research?

Our Burford calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Burford.

What are the key findings of the Burford P300 recognition memory study?

Key findings from Burford include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Burford results show statistical significance and research reproducibility.

Is the Burford research data available for academic use?

Yes, we provide access to anonymized Burford research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Burford P300 recognition memory research support?

Burford applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Burford?

Our Burford validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.