Broughton Recognition Study September 15, 2024 n=75 Participants (Broughton) 8-week Broughton study

Broughton P300 Recognition Memory Research

Comprehensive controlled study conducted in Broughton documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Broughton participants.

Broughton Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Broughton

Ethics Approval: Broughton University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Broughton facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Broughton research

Study Period: September 15 - November 10, 2024 (8 weeks) in Broughton

Broughton Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Broughton participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Broughton participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Broughton participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Broughton guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Broughton testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Broughton with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Broughton Participants
95.2%
Broughton Accuracy
318ms
Broughton P300 Latency
11.3μV
Broughton Peak Amplitude

Broughton Plain-English Summary

In simple terms, this Broughton study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Broughton.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Broughton research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Broughton, particularly for cases where objective, research-backed evidence is important.

Broughton Pre-Test System Calibration

All Broughton testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Broughton participant testing commenced.

Broughton Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Broughton channels within ±0.2% tolerance

Broughton Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Broughton parameters within specification limits

Broughton Research Methodology

Week 1: Broughton Participant Recruitment & Randomization

75 healthy adults recruited through Broughton university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Broughton participants provided informed consent and completed health screening questionnaires.

Week 1-2: Broughton Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Broughton facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Broughton Controlled Testing Protocol

Broughton innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Broughton laboratory.

Week 6-7: Broughton Polygraph Comparison Testing

All Broughton participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Broughton Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Broughton study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Broughton P300 Recognition Response Analysis

Broughton Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Broughton Guilty P300 318ms, 11.3μV Broughton Innocent P300 315ms, 4.2μV Broughton Guilty Knowledge (n=35) Broughton Innocent Control (n=40)

Figure 1: Broughton grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Broughton groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Broughton 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Broughton guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Broughton Statistical Analysis & Performance Metrics

Broughton Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Broughton Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Broughton Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Broughton Difference - 7.1 - 6.0 - 8.2 3 ± 42

Broughton Statistical Significance Testing:

  • Broughton Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Broughton Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Broughton Effect Size: η² = 0.681 (large effect)
  • Broughton Power Analysis: β = 0.999 (excellent statistical power)
  • Broughton Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Broughton Detection Performance Metrics:

Broughton Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Broughton 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Broughton Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Broughton Improvement Ratio +81% +120% +98% +101% Immediate

Broughton Post-Test System Validation

Following completion of all Broughton participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Broughton Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Broughton Maximum drift: ±0.03% over 8-week period (Excellent stability)

Broughton Recognition Memory Research Key Findings

  • Broughton 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Broughton guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Broughton system calibration remained stable within ±0.03% over 8-week study period
  • Broughton response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Broughton EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Broughton participants
  • Broughton pre/post calibration validation confirms measurement reliability and traceability

Broughton Discussion & Clinical Implications

This controlled study conducted in Broughton demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Broughton Clinical Significance:

  • Broughton Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Broughton Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Broughton Response Time: Real-time P300 detection enables immediate assessment
  • Broughton Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Broughton Quality Assurance: Complete calibration validation ensures measurement integrity
This Broughton research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Broughton Lead Researcher

Broughton Practical Applications:

  • Broughton Forensic Psychology: Evidence-based assessment of concealed information
  • Broughton Security Screening: Reliable pre-employment and periodic assessments
  • Broughton Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Broughton Research Applications: Validated tool for memory and recognition studies
  • Broughton Clinical Assessment: Objective neurological evaluation with documented accuracy

From Broughton Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Broughton study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Broughton are grounded in published science rather than subjective opinion.

How the Broughton Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Broughton
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Broughton are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Broughton P300 Research?

This Broughton recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Broughton forensic and legal teams: seeking research-backed lie detector evidence
  • Broughton clinicians: requiring objective EEG markers for recognition and memory
  • Broughton security & compliance departments: interested in advanced screening tools
  • Broughton universities & labs: looking to build on validated P300 protocols

Broughton Future Research Directions

This foundational Broughton research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Broughton Planned Studies:

  • Broughton Multi-site Validation: Replication across multiple research centers
  • Broughton Population Diversity: Performance evaluation across demographic groups
  • Broughton Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Broughton Complex Scenarios: Real-world application validation studies
  • Broughton Machine Learning Integration: AI-enhanced pattern recognition development

Broughton P300 Research & Testing Services

Based on the success of this Broughton research study, we now offer comprehensive P300 recognition memory testing services throughout the Broughton area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Broughton Service Features:

  • Broughton Professional Testing: Certified EEG technicians serving Broughton research community
  • Broughton Complete Confidentiality: Strict privacy protection throughout Broughton area
  • Broughton Same-Day Results: Immediate analysis and reporting for Broughton clients
  • Broughton Academic Support: Research collaboration and data sharing for Broughton institutions
  • Broughton Mobile Testing: On-site testing at Broughton universities and research facilities
£2999
Broughton P300 Research Session
£4999
Broughton Full Study Package
£7999
Broughton Multi-Session Research
24/7
Broughton Research Support
"The Broughton P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Broughton Cognitive Research Director

Broughton Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Broughton?

P300 recognition memory research in Broughton involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Broughton study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Broughton research?

Our Broughton calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Broughton.

What are the key findings of the Broughton P300 recognition memory study?

Key findings from Broughton include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Broughton results show statistical significance and research reproducibility.

Is the Broughton research data available for academic use?

Yes, we provide access to anonymized Broughton research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Broughton P300 recognition memory research support?

Broughton applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Broughton?

Our Broughton validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.