Broughton Street Recognition Study September 15, 2024 n=75 Participants (Broughton Street) 8-week Broughton Street study

Broughton Street P300 Recognition Memory Research

Comprehensive controlled study conducted in Broughton Street documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Broughton Street participants.

Broughton Street Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Broughton Street

Ethics Approval: Broughton Street University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Broughton Street facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Broughton Street research

Study Period: September 15 - November 10, 2024 (8 weeks) in Broughton Street

Broughton Street Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Broughton Street participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Broughton Street participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Broughton Street participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Broughton Street guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Broughton Street testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Broughton Street with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Broughton Street Participants
95.2%
Broughton Street Accuracy
318ms
Broughton Street P300 Latency
11.3μV
Broughton Street Peak Amplitude

Broughton Street Plain-English Summary

In simple terms, this Broughton Street study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Broughton Street.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Broughton Street research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Broughton Street, particularly for cases where objective, research-backed evidence is important.

Broughton Street Pre-Test System Calibration

All Broughton Street testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Broughton Street participant testing commenced.

Broughton Street Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Broughton Street channels within ±0.2% tolerance

Broughton Street Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Broughton Street parameters within specification limits

Broughton Street Research Methodology

Week 1: Broughton Street Participant Recruitment & Randomization

75 healthy adults recruited through Broughton Street university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Broughton Street participants provided informed consent and completed health screening questionnaires.

Week 1-2: Broughton Street Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Broughton Street facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Broughton Street Controlled Testing Protocol

Broughton Street innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Broughton Street laboratory.

Week 6-7: Broughton Street Polygraph Comparison Testing

All Broughton Street participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Broughton Street Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Broughton Street study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Broughton Street P300 Recognition Response Analysis

Broughton Street Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Broughton Street Guilty P300 318ms, 11.3μV Broughton Street Innocent P300 315ms, 4.2μV Broughton Street Guilty Knowledge (n=35) Broughton Street Innocent Control (n=40)

Figure 1: Broughton Street grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Broughton Street groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Broughton Street 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Broughton Street guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Broughton Street Statistical Analysis & Performance Metrics

Broughton Street Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Broughton Street Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Broughton Street Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Broughton Street Difference - 7.1 - 6.0 - 8.2 3 ± 42

Broughton Street Statistical Significance Testing:

  • Broughton Street Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Broughton Street Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Broughton Street Effect Size: η² = 0.681 (large effect)
  • Broughton Street Power Analysis: β = 0.999 (excellent statistical power)
  • Broughton Street Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Broughton Street Detection Performance Metrics:

Broughton Street Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Broughton Street 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Broughton Street Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Broughton Street Improvement Ratio +81% +120% +98% +101% Immediate

Broughton Street Post-Test System Validation

Following completion of all Broughton Street participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Broughton Street Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Broughton Street Maximum drift: ±0.03% over 8-week period (Excellent stability)

Broughton Street Recognition Memory Research Key Findings

  • Broughton Street 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Broughton Street guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Broughton Street system calibration remained stable within ±0.03% over 8-week study period
  • Broughton Street response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Broughton Street EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Broughton Street participants
  • Broughton Street pre/post calibration validation confirms measurement reliability and traceability

Broughton Street Discussion & Clinical Implications

This controlled study conducted in Broughton Street demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Broughton Street Clinical Significance:

  • Broughton Street Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Broughton Street Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Broughton Street Response Time: Real-time P300 detection enables immediate assessment
  • Broughton Street Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Broughton Street Quality Assurance: Complete calibration validation ensures measurement integrity
This Broughton Street research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Broughton Street Lead Researcher

Broughton Street Practical Applications:

  • Broughton Street Forensic Psychology: Evidence-based assessment of concealed information
  • Broughton Street Security Screening: Reliable pre-employment and periodic assessments
  • Broughton Street Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Broughton Street Research Applications: Validated tool for memory and recognition studies
  • Broughton Street Clinical Assessment: Objective neurological evaluation with documented accuracy

From Broughton Street Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Broughton Street study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Broughton Street are grounded in published science rather than subjective opinion.

How the Broughton Street Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Broughton Street
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Broughton Street are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Broughton Street P300 Research?

This Broughton Street recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Broughton Street forensic and legal teams: seeking research-backed lie detector evidence
  • Broughton Street clinicians: requiring objective EEG markers for recognition and memory
  • Broughton Street security & compliance departments: interested in advanced screening tools
  • Broughton Street universities & labs: looking to build on validated P300 protocols

Broughton Street Future Research Directions

This foundational Broughton Street research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Broughton Street Planned Studies:

  • Broughton Street Multi-site Validation: Replication across multiple research centers
  • Broughton Street Population Diversity: Performance evaluation across demographic groups
  • Broughton Street Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Broughton Street Complex Scenarios: Real-world application validation studies
  • Broughton Street Machine Learning Integration: AI-enhanced pattern recognition development

Broughton Street P300 Research & Testing Services

Based on the success of this Broughton Street research study, we now offer comprehensive P300 recognition memory testing services throughout the Broughton Street area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Broughton Street Service Features:

  • Broughton Street Professional Testing: Certified EEG technicians serving Broughton Street research community
  • Broughton Street Complete Confidentiality: Strict privacy protection throughout Broughton Street area
  • Broughton Street Same-Day Results: Immediate analysis and reporting for Broughton Street clients
  • Broughton Street Academic Support: Research collaboration and data sharing for Broughton Street institutions
  • Broughton Street Mobile Testing: On-site testing at Broughton Street universities and research facilities
£2999
Broughton Street P300 Research Session
£4999
Broughton Street Full Study Package
£7999
Broughton Street Multi-Session Research
24/7
Broughton Street Research Support
"The Broughton Street P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Broughton Street Cognitive Research Director

Broughton Street Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Broughton Street?

P300 recognition memory research in Broughton Street involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Broughton Street study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Broughton Street research?

Our Broughton Street calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Broughton Street.

What are the key findings of the Broughton Street P300 recognition memory study?

Key findings from Broughton Street include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Broughton Street results show statistical significance and research reproducibility.

Is the Broughton Street research data available for academic use?

Yes, we provide access to anonymized Broughton Street research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Broughton Street P300 recognition memory research support?

Broughton Street applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Broughton Street?

Our Broughton Street validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.