Broad Oak Recognition Study September 15, 2024 n=75 Participants (Broad Oak) 8-week Broad Oak study

Broad Oak P300 Recognition Memory Research

Comprehensive controlled study conducted in Broad Oak documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Broad Oak participants.

Broad Oak Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Broad Oak

Ethics Approval: Broad Oak University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Broad Oak facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Broad Oak research

Study Period: September 15 - November 10, 2024 (8 weeks) in Broad Oak

Broad Oak Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Broad Oak participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Broad Oak participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Broad Oak participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Broad Oak guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Broad Oak testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Broad Oak with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Broad Oak Participants
95.2%
Broad Oak Accuracy
318ms
Broad Oak P300 Latency
11.3μV
Broad Oak Peak Amplitude

Broad Oak Plain-English Summary

In simple terms, this Broad Oak study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Broad Oak.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Broad Oak research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Broad Oak, particularly for cases where objective, research-backed evidence is important.

Broad Oak Pre-Test System Calibration

All Broad Oak testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Broad Oak participant testing commenced.

Broad Oak Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Broad Oak channels within ±0.2% tolerance

Broad Oak Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Broad Oak parameters within specification limits

Broad Oak Research Methodology

Week 1: Broad Oak Participant Recruitment & Randomization

75 healthy adults recruited through Broad Oak university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Broad Oak participants provided informed consent and completed health screening questionnaires.

Week 1-2: Broad Oak Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Broad Oak facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Broad Oak Controlled Testing Protocol

Broad Oak innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Broad Oak laboratory.

Week 6-7: Broad Oak Polygraph Comparison Testing

All Broad Oak participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Broad Oak Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Broad Oak study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Broad Oak P300 Recognition Response Analysis

Broad Oak Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Broad Oak Guilty P300 318ms, 11.3μV Broad Oak Innocent P300 315ms, 4.2μV Broad Oak Guilty Knowledge (n=35) Broad Oak Innocent Control (n=40)

Figure 1: Broad Oak grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Broad Oak groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Broad Oak 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Broad Oak guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Broad Oak Statistical Analysis & Performance Metrics

Broad Oak Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Broad Oak Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Broad Oak Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Broad Oak Difference - 7.1 - 6.0 - 8.2 3 ± 42

Broad Oak Statistical Significance Testing:

  • Broad Oak Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Broad Oak Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Broad Oak Effect Size: η² = 0.681 (large effect)
  • Broad Oak Power Analysis: β = 0.999 (excellent statistical power)
  • Broad Oak Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Broad Oak Detection Performance Metrics:

Broad Oak Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Broad Oak 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Broad Oak Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Broad Oak Improvement Ratio +81% +120% +98% +101% Immediate

Broad Oak Post-Test System Validation

Following completion of all Broad Oak participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Broad Oak Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Broad Oak Maximum drift: ±0.03% over 8-week period (Excellent stability)

Broad Oak Recognition Memory Research Key Findings

  • Broad Oak 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Broad Oak guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Broad Oak system calibration remained stable within ±0.03% over 8-week study period
  • Broad Oak response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Broad Oak EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Broad Oak participants
  • Broad Oak pre/post calibration validation confirms measurement reliability and traceability

Broad Oak Discussion & Clinical Implications

This controlled study conducted in Broad Oak demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Broad Oak Clinical Significance:

  • Broad Oak Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Broad Oak Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Broad Oak Response Time: Real-time P300 detection enables immediate assessment
  • Broad Oak Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Broad Oak Quality Assurance: Complete calibration validation ensures measurement integrity
This Broad Oak research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Broad Oak Lead Researcher

Broad Oak Practical Applications:

  • Broad Oak Forensic Psychology: Evidence-based assessment of concealed information
  • Broad Oak Security Screening: Reliable pre-employment and periodic assessments
  • Broad Oak Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Broad Oak Research Applications: Validated tool for memory and recognition studies
  • Broad Oak Clinical Assessment: Objective neurological evaluation with documented accuracy

From Broad Oak Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Broad Oak study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Broad Oak are grounded in published science rather than subjective opinion.

How the Broad Oak Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Broad Oak
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Broad Oak are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Broad Oak P300 Research?

This Broad Oak recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Broad Oak forensic and legal teams: seeking research-backed lie detector evidence
  • Broad Oak clinicians: requiring objective EEG markers for recognition and memory
  • Broad Oak security & compliance departments: interested in advanced screening tools
  • Broad Oak universities & labs: looking to build on validated P300 protocols

Broad Oak Future Research Directions

This foundational Broad Oak research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Broad Oak Planned Studies:

  • Broad Oak Multi-site Validation: Replication across multiple research centers
  • Broad Oak Population Diversity: Performance evaluation across demographic groups
  • Broad Oak Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Broad Oak Complex Scenarios: Real-world application validation studies
  • Broad Oak Machine Learning Integration: AI-enhanced pattern recognition development

Broad Oak P300 Research & Testing Services

Based on the success of this Broad Oak research study, we now offer comprehensive P300 recognition memory testing services throughout the Broad Oak area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Broad Oak Service Features:

  • Broad Oak Professional Testing: Certified EEG technicians serving Broad Oak research community
  • Broad Oak Complete Confidentiality: Strict privacy protection throughout Broad Oak area
  • Broad Oak Same-Day Results: Immediate analysis and reporting for Broad Oak clients
  • Broad Oak Academic Support: Research collaboration and data sharing for Broad Oak institutions
  • Broad Oak Mobile Testing: On-site testing at Broad Oak universities and research facilities
£2999
Broad Oak P300 Research Session
£4999
Broad Oak Full Study Package
£7999
Broad Oak Multi-Session Research
24/7
Broad Oak Research Support
"The Broad Oak P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Broad Oak Cognitive Research Director

Broad Oak Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Broad Oak?

P300 recognition memory research in Broad Oak involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Broad Oak study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Broad Oak research?

Our Broad Oak calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Broad Oak.

What are the key findings of the Broad Oak P300 recognition memory study?

Key findings from Broad Oak include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Broad Oak results show statistical significance and research reproducibility.

Is the Broad Oak research data available for academic use?

Yes, we provide access to anonymized Broad Oak research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Broad Oak P300 recognition memory research support?

Broad Oak applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Broad Oak?

Our Broad Oak validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.