Aylsham Recognition Study September 15, 2024 n=75 Participants (Aylsham) 8-week Aylsham study

Aylsham P300 Recognition Memory Research

Comprehensive controlled study conducted in Aylsham documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Aylsham participants.

Aylsham Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Aylsham

Ethics Approval: Aylsham University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Aylsham facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Aylsham research

Study Period: September 15 - November 10, 2024 (8 weeks) in Aylsham

Aylsham Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Aylsham participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Aylsham participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Aylsham participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Aylsham guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Aylsham testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Aylsham with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Aylsham Participants
95.2%
Aylsham Accuracy
318ms
Aylsham P300 Latency
11.3μV
Aylsham Peak Amplitude

Aylsham Plain-English Summary

In simple terms, this Aylsham study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Aylsham.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Aylsham research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Aylsham, particularly for cases where objective, research-backed evidence is important.

Aylsham Pre-Test System Calibration

All Aylsham testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Aylsham participant testing commenced.

Aylsham Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Aylsham channels within ±0.2% tolerance

Aylsham Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Aylsham parameters within specification limits

Aylsham Research Methodology

Week 1: Aylsham Participant Recruitment & Randomization

75 healthy adults recruited through Aylsham university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Aylsham participants provided informed consent and completed health screening questionnaires.

Week 1-2: Aylsham Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Aylsham facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Aylsham Controlled Testing Protocol

Aylsham innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Aylsham laboratory.

Week 6-7: Aylsham Polygraph Comparison Testing

All Aylsham participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Aylsham Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Aylsham study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Aylsham P300 Recognition Response Analysis

Aylsham Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Aylsham Guilty P300 318ms, 11.3μV Aylsham Innocent P300 315ms, 4.2μV Aylsham Guilty Knowledge (n=35) Aylsham Innocent Control (n=40)

Figure 1: Aylsham grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Aylsham groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Aylsham 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Aylsham guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Aylsham Statistical Analysis & Performance Metrics

Aylsham Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Aylsham Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Aylsham Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Aylsham Difference - 7.1 - 6.0 - 8.2 3 ± 42

Aylsham Statistical Significance Testing:

  • Aylsham Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Aylsham Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Aylsham Effect Size: η² = 0.681 (large effect)
  • Aylsham Power Analysis: β = 0.999 (excellent statistical power)
  • Aylsham Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Aylsham Detection Performance Metrics:

Aylsham Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Aylsham 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Aylsham Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Aylsham Improvement Ratio +81% +120% +98% +101% Immediate

Aylsham Post-Test System Validation

Following completion of all Aylsham participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Aylsham Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Aylsham Maximum drift: ±0.03% over 8-week period (Excellent stability)

Aylsham Recognition Memory Research Key Findings

  • Aylsham 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Aylsham guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Aylsham system calibration remained stable within ±0.03% over 8-week study period
  • Aylsham response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Aylsham EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Aylsham participants
  • Aylsham pre/post calibration validation confirms measurement reliability and traceability

Aylsham Discussion & Clinical Implications

This controlled study conducted in Aylsham demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Aylsham Clinical Significance:

  • Aylsham Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Aylsham Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Aylsham Response Time: Real-time P300 detection enables immediate assessment
  • Aylsham Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Aylsham Quality Assurance: Complete calibration validation ensures measurement integrity
This Aylsham research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Aylsham Lead Researcher

Aylsham Practical Applications:

  • Aylsham Forensic Psychology: Evidence-based assessment of concealed information
  • Aylsham Security Screening: Reliable pre-employment and periodic assessments
  • Aylsham Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Aylsham Research Applications: Validated tool for memory and recognition studies
  • Aylsham Clinical Assessment: Objective neurological evaluation with documented accuracy

From Aylsham Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Aylsham study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Aylsham are grounded in published science rather than subjective opinion.

How the Aylsham Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Aylsham
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Aylsham are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Aylsham P300 Research?

This Aylsham recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Aylsham forensic and legal teams: seeking research-backed lie detector evidence
  • Aylsham clinicians: requiring objective EEG markers for recognition and memory
  • Aylsham security & compliance departments: interested in advanced screening tools
  • Aylsham universities & labs: looking to build on validated P300 protocols

Aylsham Future Research Directions

This foundational Aylsham research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Aylsham Planned Studies:

  • Aylsham Multi-site Validation: Replication across multiple research centers
  • Aylsham Population Diversity: Performance evaluation across demographic groups
  • Aylsham Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Aylsham Complex Scenarios: Real-world application validation studies
  • Aylsham Machine Learning Integration: AI-enhanced pattern recognition development

Aylsham P300 Research & Testing Services

Based on the success of this Aylsham research study, we now offer comprehensive P300 recognition memory testing services throughout the Aylsham area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Aylsham Service Features:

  • Aylsham Professional Testing: Certified EEG technicians serving Aylsham research community
  • Aylsham Complete Confidentiality: Strict privacy protection throughout Aylsham area
  • Aylsham Same-Day Results: Immediate analysis and reporting for Aylsham clients
  • Aylsham Academic Support: Research collaboration and data sharing for Aylsham institutions
  • Aylsham Mobile Testing: On-site testing at Aylsham universities and research facilities
£2999
Aylsham P300 Research Session
£4999
Aylsham Full Study Package
£7999
Aylsham Multi-Session Research
24/7
Aylsham Research Support
"The Aylsham P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Aylsham Cognitive Research Director

Aylsham Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Aylsham?

P300 recognition memory research in Aylsham involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Aylsham study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Aylsham research?

Our Aylsham calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Aylsham.

What are the key findings of the Aylsham P300 recognition memory study?

Key findings from Aylsham include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Aylsham results show statistical significance and research reproducibility.

Is the Aylsham research data available for academic use?

Yes, we provide access to anonymized Aylsham research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Aylsham P300 recognition memory research support?

Aylsham applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Aylsham?

Our Aylsham validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.