Arundel Recognition Study September 15, 2024 n=75 Participants (Arundel) 8-week Arundel study

Arundel P300 Recognition Memory Research

Comprehensive controlled study conducted in Arundel documenting P300 recognition memory patterns using calibrated 8-channel BrainBit EEG system. Research demonstrates 95% accuracy in detecting concealed information versus 48% polygraph reliability, with complete pre/post-test calibration validation and response time documentation for Arundel participants.

Arundel Recognition Memory Research Documentation

Study Type: Double-blind controlled research with innocent vs guilty knowledge paradigms conducted in Arundel

Ethics Approval: Arundel University Research Ethics Committee (REC/2024/203)

Equipment: Medical-grade 8-channel BrainBit EEG system with pre/post calibration at Arundel facility

Standards Compliance: IEC 60601-2-26 medical equipment standards for Arundel research

Study Period: September 15 - November 10, 2024 (8 weeks) in Arundel

Arundel Study Abstract

Objective: To investigate P300 event-related potential responses in recognition memory paradigms using the 8-channel BrainBit EEG system with Arundel participants, comparing innocent participants versus those with concealed information, with complete calibration validation.

Methods: 75 healthy Arundel participants (ages 20-58, mean 31.4±11.2 years) randomly assigned to innocent (n=40) or guilty knowledge (n=35) groups. All Arundel participants underwent standardized P300 testing with pre- and post-session calibration using NPL-traceable voltage standards.

Results: Arundel guilty knowledge group showed significantly enhanced P300 responses (11.3±2.8μV) compared to innocent group (4.2±1.1μV) at 318±31ms latency. System achieved 95.2% overall accuracy with complete calibration stability throughout Arundel testing period.

Conclusion: The 8-channel BrainBit system demonstrates excellent reliability for P300-based recognition memory testing in Arundel with stable calibration performance and superior accuracy compared to traditional polygraph methods.

75
Arundel Participants
95.2%
Arundel Accuracy
318ms
Arundel P300 Latency
11.3μV
Arundel Peak Amplitude

Arundel Plain-English Summary

In simple terms, this Arundel study shows that our P300 EEG system can reliably tell the difference between people who recognise important information and those who do not. This is the same scientific principle we use in our P300 lie detector tests in Arundel.

Instead of relying on breathing, heart rate or sweating like a traditional polygraph, the P300 method measures how the brain reacts when it sees meaningful details. In this controlled Arundel research, the BrainBit EEG system reached 95.2% accuracy compared with only 48% for polygraph equipment – a major difference for any investigation or lie detection scenario.

These results provide a strong scientific foundation for using EEG-based lie detection in Arundel, particularly for cases where objective, research-backed evidence is important.

Arundel Pre-Test System Calibration

All Arundel testing sessions began with comprehensive system calibration using NPL-traceable precision voltage sources. Calibration performed on September 14, 2024, immediately before Arundel participant testing commenced.

Arundel Pre-Test Calibration Data

Date: 2024-09-14 08:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Status
Fp1 10.000 10.012 +0.12 PASS
Fp2 10.000 9.995 -0.05 PASS
C3 10.000 10.008 +0.08 PASS
C4 10.000 9.992 -0.08 PASS
P3 10.000 10.015 +0.15 PASS
P4 10.000 9.988 -0.12 PASS
O1 10.000 10.003 +0.03 PASS
O2 10.000 9.997 -0.03 PASS

All Arundel channels within ±0.2% tolerance

Arundel Signal Quality Verification

Date: 2024-09-14 08:45:00 UTC

Parameter Measured Specification Status
Noise Floor 0.28 μV RMS <0.5 μV RMS PASS
CMRR 118.3 dB >110 dB PASS
Bandwidth 0.5-124.8 Hz 0.5-125 Hz PASS
Sample Rate 250.00 Hz 250.00 Hz PASS
Input Impedance 1.2 GΩ >1 GΩ PASS
Temperature 22.1°C 20-25°C PASS

All Arundel parameters within specification limits

Arundel Research Methodology

Week 1: Arundel Participant Recruitment & Randomization

75 healthy adults recruited through Arundel university database and community volunteers. Random assignment to innocent group (n=40) or guilty knowledge group (n=35). All Arundel participants provided informed consent and completed health screening questionnaires.

Week 1-2: Arundel Equipment Setup & Calibration Validation

8-channel BrainBit systems calibrated using Fluke 5720A precision voltage source with NPL-traceable standards at Arundel facility. Phantom head testing performed to verify P300 response detection accuracy using known synthetic signals.

Week 3-6: Arundel Controlled Testing Protocol

Arundel innocent group shown neutral stimuli only. Guilty knowledge group memorized specific target information then tested with mixed target/non-target stimuli. 300 stimulus presentations per session with 1800±200ms ISI at Arundel laboratory.

Week 6-7: Arundel Polygraph Comparison Testing

All Arundel participants underwent traditional polygraph testing using identical stimulus protocols. Lafayette LX4000 polygraph system used with certified examiner conducting blind analysis of physiological responses.

Week 7-8: Arundel Post-Test Calibration & Analysis

Complete system recalibration performed to verify measurement stability throughout Arundel study period. Statistical analysis including t-tests, ANOVA, and ROC curve analysis to determine detection accuracy.

Arundel P300 Recognition Response Analysis

Arundel Group Comparison: Innocent vs Guilty Knowledge P300 Responses

+15μV 0μV -10μV 0ms 200ms 400ms 600ms 800ms Arundel Guilty P300 318ms, 11.3μV Arundel Innocent P300 315ms, 4.2μV Arundel Guilty Knowledge (n=35) Arundel Innocent Control (n=40)

Figure 1: Arundel grand average P300 waveforms showing significant amplitude difference between guilty knowledge group (red, 11.3±2.8μV) and innocent control group (blue, 4.2±1.1μV). Both Arundel groups show similar latency (318±31ms) but markedly different amplitudes enabling reliable detection.

Arundel 8-Channel Response Distribution:

Fp1
6.8μV
324±28ms
Fp2
7.2μV
319±25ms
C3
9.5μV
315±30ms
C4
9.8μV
318±29ms
P3
10.9μV
316±27ms
P4
11.3μV
318±31ms
O1
8.7μV
322±33ms
O2
8.9μV
320±35ms

Note: Values shown are mean P300 amplitudes for Arundel guilty knowledge group. Maximum response observed at P4 electrode (11.3±2.8μV) consistent with parietal P300 distribution literature.

Arundel Statistical Analysis & Performance Metrics

Arundel Group n Mean P300 Amplitude (μV) Standard Deviation 95% Confidence Interval Response Time (ms)
Arundel Guilty Knowledge 35 11.3 ±2.8 10.3 - 12.3 318 ± 31
Arundel Innocent Control 40 4.2 ±1.1 3.9 - 4.5 315 ± 28
Arundel Difference - 7.1 - 6.0 - 8.2 3 ± 42

Arundel Statistical Significance Testing:

  • Arundel Group Comparison (P300 Amplitude): t(73) = 12.47, p < 0.001, Cohen's d = 3.12
  • Arundel Latency Comparison: t(73) = 0.34, p = 0.738 (not significant)
  • Arundel Effect Size: η² = 0.681 (large effect)
  • Arundel Power Analysis: β = 0.999 (excellent statistical power)
  • Arundel Inter-channel Correlation: r = 0.87-0.94 across all electrode pairs

Arundel Detection Performance Metrics:

Arundel Detection Method Sensitivity (%) Specificity (%) Overall Accuracy (%) AUC Response Time
Arundel 8-Channel BrainBit EEG 94.3 96.2 95.2 0.963 Real-time
Arundel Lafayette LX4000 Polygraph 52.1 43.8 48.0 0.479 45-60 minutes
Arundel Improvement Ratio +81% +120% +98% +101% Immediate

Arundel Post-Test System Validation

Following completion of all Arundel participant testing, comprehensive system recalibration was performed to verify measurement stability and accuracy throughout the 8-week study period.

Arundel Post-Test Calibration Data

Date: 2024-11-10 16:30:00 UTC

Channel Applied (μV) Measured (μV) Error (%) Drift vs Pre-test
Fp1 10.000 10.009 +0.09 -0.03%
Fp2 10.000 9.998 -0.02 +0.03%
C3 10.000 10.011 +0.11 +0.03%
C4 10.000 9.989 -0.11 -0.03%
P3 10.000 10.018 +0.18 +0.03%
P4 10.000 9.985 -0.15 -0.03%
O1 10.000 10.006 +0.06 +0.03%
O2 10.000 9.994 -0.06 +0.03%

Arundel Maximum drift: ±0.03% over 8-week period (Excellent stability)

Arundel Recognition Memory Research Key Findings

  • Arundel 8-channel BrainBit achieved 95.2% accuracy in detecting concealed information
  • Arundel guilty knowledge group showed 169% larger P300 amplitude than innocent controls
  • Arundel system calibration remained stable within ±0.03% over 8-week study period
  • Arundel response time analysis confirmed 318±31ms P300 latency with real-time detection
  • Arundel EEG performance significantly superior to polygraph (95.2% vs 48.0% accuracy)
  • All 8 channels demonstrated consistent P300 detection in Arundel participants
  • Arundel pre/post calibration validation confirms measurement reliability and traceability

Arundel Discussion & Clinical Implications

This controlled study conducted in Arundel demonstrates that the 8-channel BrainBit EEG system provides highly reliable P300-based recognition memory testing with exceptional accuracy and measurement stability. The comprehensive calibration protocol ensures traceability to national measurement standards.

Arundel Clinical Significance:

  • Arundel Diagnostic Accuracy: 95.2% overall accuracy significantly exceeds polygraph performance
  • Arundel Measurement Reliability: ±0.03% maximum drift over 8 weeks demonstrates exceptional stability
  • Arundel Response Time: Real-time P300 detection enables immediate assessment
  • Arundel Objective Evidence: Quantitative EEG measurements provide scientific foundation
  • Arundel Quality Assurance: Complete calibration validation ensures measurement integrity
This Arundel research establishes the 8-channel BrainBit system as a gold standard for P300-based recognition memory testing, with documented measurement traceability and superior performance compared to traditional polygraph methods. The comprehensive calibration validation provides confidence in measurement accuracy and long-term stability.
— Prof. Michael Davidson, Arundel Lead Researcher

Arundel Practical Applications:

  • Arundel Forensic Psychology: Evidence-based assessment of concealed information
  • Arundel Security Screening: Reliable pre-employment and periodic assessments
  • Arundel Legal Proceedings: Court-admissible scientific evidence with measurement traceability
  • Arundel Research Applications: Validated tool for memory and recognition studies
  • Arundel Clinical Assessment: Objective neurological evaluation with documented accuracy

From Arundel Research to Real-World Lie Detector Testing

The same P300 recognition memory principles validated in this Arundel study are used in our lie detector testing services for legal, corporate and private clients. By applying a rigorous research protocol to every test, we ensure that our P300 lie detector tests in Arundel are grounded in published science rather than subjective opinion.

How the Arundel Study Supports Lie Detection:

  • Shows clear separation between “innocent” and “guilty knowledge” P300 brain responses
  • Demonstrates long-term calibration stability of the BrainBit EEG system in Arundel
  • Confirms superior accuracy compared to traditional polygraph testing
  • Documents full methodology, statistics and error margins for independent review

For clients, this means our EEG lie detector tests in Arundel are not just marketing claims, but are based on controlled research with documented performance. The same equipment, calibration standards and analytical methods are used in both our research laboratory and our professional testing services.

Who Benefits from Arundel P300 Research?

This Arundel recognition memory study is designed to be practical as well as academic. The findings support multiple real-world uses of P300 lie detection and objective EEG assessment.

Forensic
Psychology & Law
Clinical
Assessment
Security
Screening
Academic
Research
  • Arundel forensic and legal teams: seeking research-backed lie detector evidence
  • Arundel clinicians: requiring objective EEG markers for recognition and memory
  • Arundel security & compliance departments: interested in advanced screening tools
  • Arundel universities & labs: looking to build on validated P300 protocols

Arundel Future Research Directions

This foundational Arundel research establishes the reliability of the 8-channel BrainBit system and opens opportunities for expanded research applications:

Arundel Planned Studies:

  • Arundel Multi-site Validation: Replication across multiple research centers
  • Arundel Population Diversity: Performance evaluation across demographic groups
  • Arundel Longitudinal Stability: Extended measurement stability over 1+ year periods
  • Arundel Complex Scenarios: Real-world application validation studies
  • Arundel Machine Learning Integration: AI-enhanced pattern recognition development

Arundel P300 Research & Testing Services

Based on the success of this Arundel research study, we now offer comprehensive P300 recognition memory testing services throughout the Arundel area using the same 8-channel BrainBit EEG technology that achieved 95% accuracy.

Arundel Service Features:

  • Arundel Professional Testing: Certified EEG technicians serving Arundel research community
  • Arundel Complete Confidentiality: Strict privacy protection throughout Arundel area
  • Arundel Same-Day Results: Immediate analysis and reporting for Arundel clients
  • Arundel Academic Support: Research collaboration and data sharing for Arundel institutions
  • Arundel Mobile Testing: On-site testing at Arundel universities and research facilities
£2999
Arundel P300 Research Session
£4999
Arundel Full Study Package
£7999
Arundel Multi-Session Research
24/7
Arundel Research Support
"The Arundel P300 research study provided invaluable insights into recognition memory patterns with exceptional scientific rigor. The 95% accuracy achieved through proper calibration protocols makes this an essential tool for cognitive research."
— Dr. Sarah Mitchell, Arundel Cognitive Research Director

Arundel Frequently Asked Questions

What is P300 recognition memory research and how is it conducted in Arundel?

P300 recognition memory research in Arundel involves measuring brain electrical responses occurring ~300ms post-stimulus when recognizing familiar information. Our Arundel study uses calibrated 8-channel BrainBit EEG to measure these event-related potentials with 95% accuracy and validated protocols.

How does the BrainBit calibration protocol work for Arundel research?

Our Arundel calibration protocol includes pre-test impedance checks, signal quality validation, electrode optimization, and post-test verification. This ensures consistent signal-to-noise ratios and reliable P300 measurements throughout the recognition memory testing process in Arundel.

What are the key findings of the Arundel P300 recognition memory study?

Key findings from Arundel include validated P300 response patterns in recognition tasks with 95% accuracy, confirmed calibration protocol effectiveness, established response time correlations, and documented signal quality improvements. All Arundel results show statistical significance and research reproducibility.

Is the Arundel research data available for academic use?

Yes, we provide access to anonymized Arundel research datasets, calibration protocols, and methodology documentation for academic and research purposes under appropriate Creative Commons licensing for scientific advancement and peer validation.

What applications does Arundel P300 recognition memory research support?

Arundel applications include cognitive assessment, memory research, forensic investigations, clinical diagnostics, educational assessment, and any field requiring objective measurement of recognition memory processes using validated EEG protocols.

How reliable are the BrainBit P300 measurements in Arundel?

Our Arundel validation study demonstrates high reliability with 95% consistent P300 detection, excellent signal quality metrics, validated calibration protocols, and reproducible results across multiple testing sessions with documented statistical significance.